Loading...
Freeport NIP(6)-LR 980720CONTRA CT INSPECTION SER VICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889 REPORT OF METAL DECK INSPECTION Project: Client: Freeport North Distribution Center Coppell, TX Reed Engineering Group 2424 Stutz, Suite 400 Dallas, TX 75235 Drawings utilized: Report No: 9987-8 Attention: Keith Atkins Date of Service: 07-20-98 Page 1 of 1 REPORT OF INSPECTION Contract Documents/AWS D 1.1-96 Locations/item inspected: Column line 1 to 5 and grid line F to M Discrepancies/comments: A visual inspection was conducted on the above referenced project with results as follows: 1 .) Steel deck was found non-compliant due to: a.) Missing welds b.) Missing side lap screws c.) Side lap screws only penetrating one (1) sheet d.) Weld pattern not starting at side lap Note: Inspection of this area was stopped due to the amount of discrepancies found. Recommend erector go through entire metal roof system and verify. Technician ~ract Inspection Service This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client