Freeport NIP(2.5)-LR 980715F:IEEE! L E r-lEVi I FIE E I=IIr-ir~
GEOTECHNICaL AND r~ F~I r-I II p
ENVIRONMENTAL CONSULTANTS
REPORT OF BUILT-UP ROOFING OBSERVATION
Northpoint Distribution Center
Royal Lane at Northpoint Drive
Coppell, Texas
REPORTED TO: Myers & Crow Company, Ltd. REPORT NO. 73
3811 Turtle Creek Boulevard REPORT DATE: 07-15-98
Suite 730 REG PROJECT NO. 4115
Dallas, Texas 75219 DATE OBSERVED: 07-01-98
ATTN: Mr. Richard Crow TECHNICIAN: T. Belew
PAGE: 1 of 2
~ McFadden & Miller ~ Clear
~t Wind River Roofing 84°/98°
Roof column line D to G and from 21 to 26
Application of insulation board, 1 cricket covered with 4 plys of
fiberglass felt paper using hot asphalt to attach each ply. Also,
marked area for fishmouth and dry caps.
~1 Insulation: 15,680 Sq.ft Membrane: 15,680 Sq.ft
Roofing Materials As Specified: X Roof Sketch Attached: X
Labels Attached: X Debris Removed from Roof Surface: X
Material'Sheet Attached: X Crickets Installed: X
Materials Stored as Required: X Deck Inspected: X
Non Conforming Materials Noted: X Photograph's taken this Date: X
Pull Test and/or Adhesion Test Performed: X Attachments: X
): I 450° +/-25F I
Asphalt / Pitch Kettle Temperature: Time Temp. Application (EVT): Time Temp.
Type IIIAsphalt 7:30 am 538° 7:45am 502°
Comments: Roofing foreman was notified of kettle temperature. Temperature was reduced.
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FaX [214] 350 0019
REPORT NO. 73
REPORT DATE: 07-15-98
REG PROJECT NO. 4115
DATE OBSERVED: 07-01-98
PAGE: 2 of 2
Distribution: (4) Myers & Crow Company, Ltd./ Submitted by:
Mr. Richard Crow
(1) AECC, Inc./Mr. Jimmy Schwartz REED ENGINEERING GROUP, INC.
(1) Dockery Engineering/
Mr. Bill Wray Original Signed By
(1) McFadden & Miller/
Mr. Jon Jacobson Keith Atkins
(1) Halff Associates/Mr. Pat Acker BW/cav
(1) Pritchard Associates/
Mr. Jim Pritchard
(1) O'Bden & Associates/
Mr. Mick Granlund
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone