ST0004-LR010821 '~r~'A'~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
-- Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement (1) Quantam Contracting
Repair
TMI Report No.: DC01-066-043
Report Date: 08/21/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 08/14/2001
Slump 5 in max Sampled By Zuhair Shubbar
Air Content 3 % min 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 816571 Time Batched: n/a Time Sampled: 12:50 pm
Slump: 7 in* Air Content: 3.0 % Unit Weight: n/a
Concrete Temperature: 93° F Ambient Temperature: 97° F Yardage (c.y.): 60 of 90
Placement Location: Roadway paving
Sample Location: Repair no. 15, West bound lane of N. Freeport Pkwy. at 130' Nodh form starting point of repair
An asterisk (*) appears next to field data which does NOT meet specifications.
Cylinder Age, Max Load Area Strength Fracture
Set # # Test Date (days) (lbs. force) (sq.in.) (psi] Type
1 08140101 08/21/2001 7 112440 28.27 3980 unbonded cap
1 08140102 08/21/2001 7 120830 28.27 4270 unbonded cap
1 08140103 08/28/2001 14
1 08140104 08/28/2001 14
1 08140105 09/11/2001 28
1 08140106 09/11/2001 28
Normal cylinder size: 6"x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
,.---.-.-..--.--........
TERRA-MAR, INC.
Tho rosults presented in this report pertain only to the s~ocific itoms tested. This report was produce~ for the oxclusivo use of the client. Any reproduction
this ropo~, or any part therein, is stdctly prohibited without the oxpross wdttea consent of
Page I of l