ST0004-LR010820 (3) l'--/~,J~-~J~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGWEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
-- Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement (1) Quantam Contracting
Repair
TMI Report No.: DC01-066-034
Report Date: 08/20/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 08/0~/2001
Slump 5 in max Sampled By Adrain Hayes
Air Content 3 % min 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 937433 Time Batched: 10:33 am Time Sampled: 11:45 am
Slump: 5.5 in* Air Content: 4.5 % Unit Weight: n/a
Concrete Temperature: 96° F Ambient Temperature: 98° F Yardage (c.y.): 10 of 130
Placement Location: North side of Freeport Pkwy.
Sample Location: Station 14+00 to Station 7+50
An asterisk (*) appears next to field data which does NOT meet specifications.
Set # Cyl~der Age, Max Load Area Strength Fracture
Test Date (days,) (lbs. force) (sq.in.) (psi'~ Type
1 08020101 08/09/2001 7 106690 28.27 3770 unbonded cap
1 08020102 08/09/2001 7 103100 28.27 3650 unbonded cap
1 08020103 08/16/2001 14 118610 28.27 4190 unbonded cap
1 08020104 08/16/2001 14 117270 28.27 4150 unbonded cap
I 08020105 08/30/2001 28
1 08020106 08/30/2001 28
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
Sr. Vic~r~ident
The results presented in this repoA pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this repod, or any pad therein, is strictly prohibited without the express written consent of TMI.
Page I o~2