Loading...
ST0004-LR010820 (5) 'lr~,J~L-I~n GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 1105CAbles Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 ? - - Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-035 Report Date: 08/20/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 08/03/2001 Slump 5 in max Sampled By 7uhair Shubbar Air Content 3 % min 6 % max Weather Pt. Cloudy Concrete Temperature n/a Supplier/Mix Hanson/9836 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 937508 Time Batched: 12:15 pm Time Sampled: 12:50 pm Slump: 6 in* Air Content: 6.0 % Unit Weight: n/a Concrete Temperature: 93° F Ambient Temperature: 97° F Yardage (c.y.): 30 of 60 Placement Location: Paving Sample Location: Repair, #15 North Freeport Pkwy. An asterisk (*) appears next to field data which does NOT meet specifications. Cylinder Age. Max Load Area Strength Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi'} Type 1 08030101 08/10/2001 7 110390 28.27 3900 unbonded cap 1 08030102 08/10/2001 7 108970 28.27 3850 unbonded cap 1 08030103 08/17/2001 14 121300 28.27 4290 unbonded cap I 08030104 08/17/2001 14 121130 28.27 4280 unbonded cap I 08030105 08/31/2001 28 I 08030106 08/31/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMt are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. Sr~e ~eside~t The results presented in this report pe~ain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI.