PA0101-LR010803CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy,, Suite #100 Report Number: 94011093.0028 Dallas, Texas 75247 (214) 630-1010 Service D~01 Clien~'~tY of CoppeJ~,~rk~Recreation Rape, [ Attn: Brad Reid ~' *~A ~ 732 DeForest ~[ CoppelITX77 Mat&rial Inform~ion Specifi~ 3000 psi @ 28 Days 12:00pm Date Cast: July 26, 2001 Technician: Albert Garcia Batch Time: 11:44am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 10 Truck No: 110 Ticket No: 2947979 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: Sidewalk: See attached sketch Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: 4.0 3-6 ASTM C-231 Concrete Temperature,o F: 92 ASTM C-1064 Ambient Temperature, o F: 90 ASTM C-1064 Plastic Unit Weight, pcf: ~,,1~ $/ Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area ,~'~ ~~fll~f Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 jf~,, I1~,v 08/02/2001 I 2 6.00 28.27 ~ I/ 08/02/2001 Average 3,490 1 3 08/23/2001 28 1 4 08/23/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ASTM C-31, C-39, C-172, C-1231 Technician: Albert Garcia Report Distribution: ~ring, Inc. (1) city of Coppell - Parks & Recreation (1) TLB Construction Reviewed by: (1) city of coppell - Constr. Insp. ~ Eric J.~leveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not bo reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1