Loading...
PA0101-LR010810CONCRETE COMPRESSIVE STRENGTH TEST .H.~ EN~NEERING, INC. 8901 Carpenter Rwy., Suite #100 Report Number: 94011093.0024 Dallas, Texas 75247 Service Date.' ~J'~ ?.,?01 63O-lOl Citv~Q~l~ll~- Park~ & Recreation Report igust 10, 2001 Client: ~l~n:~' ~"B~ad Reid ~,l Proje( :rew Brown Park East ~oore Road /732 DeForest f Coppell, Texas ~ppe~9 Proj, Number: 940110 Material Information Sa )n Specified Strength: 3000 psi (~ 28 Days Sample Time: 8:05am Date Cast: July 12, 2001 Technician: Sammy Cardona Batch Time: 7:43am Plant: 41 Weather Conditions: Clear, sunny Supplier: TXI Accumulative Yards: 80 Truck No: 58 Ticket No: 1921042 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 15' E, 20' N of plaza area Placement Location: Plaza area Field Test Data Test Result Specification Test Method Slump, inches: 5.25 3-5 ASTM C-143 Air Content, %: Concrete Temperature,° F: 90 ASTM C-1064 Ambient Temperature, 0 F: 85 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 07/19/2001 7 76,810 2,720 1 2 6.00 28.27 07/19/2001 7 75,480 2,670 Average 2,700 I 3 6.00 28.27 08/09/2001 28 86,200 I 4 6.00 28.27 08/09/2001 28 98,230 ' --- t 74__/0_ .~)-- Average Services - Obtain samples of fresh concrete at the placement locations, perform required field test,t~d'nd cast compressive strength samples. ^STM C-31, C-39, C-172, C-1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 · CONCRETE COMPRESSIVE STRENGTH TEST ENO~NF.E~.D~o [NC. 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0024 Dallas, Texas 75247 Service Date: July 12, 2001 (214) ~3o-lolo Client: City of Coppell - Parks & Recreation Report Date: August 10, 2001 ^ttn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 8:55am Date Cast: July 12, 2001 Technician: Sammy Cardona Batch Time: 8:21 am Plant: 41 Weather Conditions: Clear, sunny Supplier: TXI Accumulative Yards: 130 Truck No: 111 Ticket No: 1921049 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 20' W, 15' N of plaza area Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: Concrete Temperature,o F: 92 ASTM C-1064 Ambient Temperature, o F: 88 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 07/19/2001 7 101,510 3,590 2 2 6.00 28.27 07/19/2001 7 102,620 3,630 Average 3,610 2 3 6.00 28.27 08/09/2001 28 128,520 4,540 2 4 6.00 28.27 08/09/2001 28 134,510 4,760 Average 4,650 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ASTM C-31, C-39, C-172, C-1231 Technician: Sammy Cardona (1) City of Coppell- Parks & Recreation (1) TLB Construction Reviewed by: (1) City of Coppell - Constr. Insp. ~ Eric J.~eiand, P.E. Senior Project Engine~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples teated at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 o~*u.~,,o~*~,~