WA9302-CS 940112From the desk of... Ken Griffin, P.E. GEOTECHNICAL GEE Consultants, Inc. EI NVIRONMENTAL 2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794 January 05, 1994 City of Coppell 255 Parkway Boulevard Coppell, Texas 75019 Attention: Mr. Ken Griffin, P.E. Proposal No.01401 Geotechnical Investigation Proposed At-Grade Water Storage Tank Coppell, Texas Dear Mr. Griffin: In accordance with our meeting of January 03, 1994, we are pleased to submit the following cost estimate for geotechnical engineering services on the above referenced project. We understand that the proposed project consists of an at-grade water storage tank to be located near the northeast corner of MacArthur Boulevard and Sandy Lake Road. As discussed, to your knowledge, an existing tank west of the proposed site is performing well from a structural standpoint. Consequently, consideration should be given to utilizing a similar foundation as an alternative. It is our understanding the existing storage tank is supported on piers with a slab supported at grade. Based on this information, requirements for this geotechnical investigation will include design parameters for a pier foundation and a slab supported at grade. Recommendations for an integral slab and grade beam foundation will be provided if soil conditions warrant this system to be a feasible alternative. As recommended, three (3) borings will be advanced in the proposed tank area. Based on our telephone conversation with Mr. Nick Legatos of The Preload Company, contractor for the first tank, piers for the existing tank were drilled to as deep as thirty-eight (38) feet and relatively shallow groundwater was encountered. Consequently, we recommend advancing our test borings to a depth of forty-five (45) feet. City of Coppeil January 05, 1994 We anticipate that the following drilling and laboratory tests will be required: Intermittent Sample Borings (approximately 135 total linear feet of borings) 4 to 6 Atterberg Limits Tests and/or Percent Passing a No. 200 U.S. Sieve 10 to 16 Moisture Content Determinations 30 to 40 Field Standard Penetration Tests and/or Unconfined Compressive Strength Tests 0 to 2 Pressure and/or Free Swell Tests This proposal is based on the assumption that the site is accessible to truck mounted drilling equipment. Soil sampling in cohesive soils will be performed with thin wail Shelby tubes in generai accordance with ASTM D1587. Granular or hard soils/rock will be sampled with a split spoon sampler in generai accordance with ASTM D1586. Soil samples will be extruded and sealed at the site and transported to our laboratory for testing. Groundwater levels in each boring will be measured at the completion of each boring and at the end of the working day. A laboratory testing program will be assigned by a geotechnicai engineer to meet the particular needs of the project after visuaily examining soil samples collected. Using periodicaily caiibrated equipment, our experienced laboratory technicians will be performing the anticipated tests listed above. A written engineering report will be prepared by a registered engineer with expertise in geotechnicai engineering. The report will include the following findings and recommendations: ft. Plan of Borings, Logs of Boring ,/2. Results of Laboratory Testing 3. Site Observations and Comments ~4. Foundation Type Selection and Design Parameters "5. Estimated Differential Vertical Movement at Test Boring Locations '6. Subgrade Preparation Procedures q. Criteria for Placement and Processing of Fill Materiais These services will be performed in accordance with our standard fee schedule. Based on information presently available and our experience, the estimated cost of this investigation, including three (3) borings, will be $2,700.00. This cost includes a meeting to discuss our findings (if desired) at the completion of our investigation . Supplemental meetings and/or GEE Consultants, Inc. Proposal No. 01401 Page 2 City of CoDpell January 05, 1994 recommendations not included in the original anticipated scope of work may be assessed using our standard rates. If near surface soft soils are encountered and consolidation testing and settlement analysis is recommended, consolidation with hysteresis tests can be performed for $300.00 each. The cost for consolidation testing would be in addition to the $2,700.00 estimated cost of the investigation. This additional testing would not be performed without prior authorization. We anticipate 1% to 2¼ weeks for completion of this investigation, weather permitting. If consolidation testing is necessary, we anticipate three (3) to five (5) weeks for completion of the investigation. We understand that we have been selected for this project and therefore, when providing this estimate, are not in violation of the engineering laws governing procurement of professional engineering contracts with public entities. If this proposal is acceptable to you, please sign the enclosed copy along with the Agreement for Geotechnical Engineering Services, and mall it to us at your earliest convenience. Thank you for the opportunity to be of service to you. Should you have any questions, please do not hesitate to contact us at your convenience. Very truly yours, GEE Consultants, Inc. Gary G. Huang, Ph. D. Project Manager Geotechnical Engineering D ivi sion GGH:RWG/bf Richard W. Gee, P.E. President Eric. GEE Consultants, Inc. Proposal No. 01401 Page 3 AGREEMENT FOR GEOTECHNICAL ENGINEERING SERVICES THIS AGREEMENT is by and between City of Coppell 255 Parkway Boulevard, Coppell, Texas 75019 hereinafter called CLIENT and GEE CONSULTANTS, INC., a Texas corporation, hereinafter called GEE, who agree as follows: 1. DECLARATIONS. CLIENT desires to engage GEE to provide Geotechnical Engineering services in connection with CLIENT's project ("THE PROJECT") described as follows: Proposed At-Grade Water Storage Tank Coppell, Texas GEE has provided a proposal and/or fee schedule to CLIENT for Geotechnical Engineering services, which fee schedule is acceptable to CLIENT. conditions" Agreement. EXECUTED THIS SCOPE OF WORK. GEE shall provide Geotechnical Engineering services for THE PROJECT in accordance with the accompanying proposal "scope of services" made a part hereof as Exhibit "A" and the "terms and set forth on the back of and made a part of this TO BE COMPLETED BY CLIENT: FOR PAYMENT OF SERVICES: 1)~h day of January , 1994 . Title: President Firm: Clty nf Coppall Address: )55 PRrkw~y Rlvd. Coppe11. Texas Zip Code: 75019 Attention: Kenneth M. Griffin- Title: Invoice to the Account of= WA 93-02 Phone No. (214) 393--1016 City Engineer FOR APPROVAL OF INVOICE(S): If the invoice is to be mailed for approval to someone other than the account charged, please indicate where to mail the invoice in the space below. Firm: Address: Zip Code: Phone No. Attention: Title: TERMS AND AGREEMENT BETWEEN E CONSULTING MISCELLANEOUS INFORMATION CONDITIONS TO GEeTECHNICAL ENGIr T~ AND STANDARD OF CARE THE CLIENT The client and/or his architect and/or his engineer shall provide the Geetechnical Engineer with all information concerning the site which is the subject matter of this contract specifically including but not limited to geetechnical information testing reports, site plan, utility easements and locations and building locations and other such information which would be of benefit to the Geotechnical Engineer in preparing and/or completing its work. The Geetechnical Engineer shall have the right to rely upon the accuracy of the information provided in performing its service. RIGHT OF ENTRY The client will provide for right of entry of the Geetechnical Engineer and all necessary equipment, in order to complete the work. While the Geetechnical Engineer will take all reasonable precautions to minimize any damage to the properly, it is understood by the client that in the normal course of work some damage may occur, the correction of which is not pa~ of this Agreement. In the prosecution of his work, the Geotechnical Engineer will take all reasonable precautions to avoid damage or injury to subteerancan structures or utilities. The client agrees to hold the Geetechnical Engineer harmless for any damages to subterranean structores which are not called to Geetechnical Enginccr's attention and correctly shown on the plans furnished which Indemnity Agreement shall specifically protect the Geetechnical Engineer. SAMPLES Geetechnical Engineer will retain all soil and rock samples for thirty (30) days. Further storage or transfer of samples can be made at owner expense upon written request. INVOICES Geetechnical Engineer will submit invoices to the client monthly and a final bill upon completion of services. Payment is due upon presentation of invoice and is past due thirty (30) days from invoice date. The client agrees to pay a finance charge of one and one-half percent (11/2%) per month, or the maximum rate allowed by law, on past due accounts, whichever is less. Service performed by the Geetechnical Engineer under this Agreement will be conducted in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. No warranty, express or implied, is made. The client recognizes that subsurface conditions may vary from those encountered at the location where borings, surveys, or explorations are made by the Geotechnical Engineer and that the data, interpretations and recommendations of the Geetechnical Engineer are based solely on the information available to him. The Geetechnical Engineer's responsibility shall be to develop data, interpretations and recommendations in a reasonably prudent manner exercising the care and skill noted in the preceding paragraph. The Geetechnical Engineer shall not be responsible for the interpretation or use by others of the information developed. INSURANCE Geetechnical Engineer agrees to indemnify and save the client harmless from and against any loss, damage, or liability arising from any negligent acts by Geetechnical Engineer, his agents, staff, and consultants employed by him. The Geetechnical Engineer shah not be responsible for any loss, damage or liability beyond the amounts, limits, and conditions of Geotcchnical Engineer's insurance. The Ge, otechnical Engineer shall not be responsible for any loss, damage, or liability arising from any acts by the client, his agents, staff, and other consultants employed by him. TERMINATION This Agreement may be terminated by either party upon seven (7) days written notice in the event of substantial failure by the other party to perform in accordance with the terms hereof. Such termination shall not be effective if that substantial failure has been remedied before expiration of the period specified in the wriugn notice. In the event of termination, Geetechnical Engineer shall be paid for services performed to the termination notice date plus reasonable termination expenses. In the event of tetminetion, or suspetmion for more than three ('3) months, prior to completion of all reports contemplated by this Agreement, Geetechnical Engineer may complete inch analyses and records as are necessary to complete his files and may also complete a report on the services performed to the date of notice of termination or suspension. The expenses of termination or suspension shall include all direct costs of Geetechnical Engineer in completing such analyses, records, and re, ports. OWNERSHIP OF DOCUMENTS ASSIGNS All reports, boring logs, field notes, laboratory test data, calculations, estimates, and other documents prepared by the Gentechnical Engineer, as instruments of service, shall remain the property of the Geetechnical Engineer. It is specifically undemood and a~ that all reports, boring logs, field data, field notes and laboratory test data, calculations, estimates, and other documents were prepared at a specific time and under a specific set of criteria for use by the client GEE CONSULTANTS, INC. named herein. ~t I~' ^u.., ,. -'.i ' d.'..d r'~t o, ak-- :'fit' ";'- -_t d _id.~.. The client agrees that all reports and other work furnished to the client or his agents, which are not paid for, will be returned upon demand and will not be used by the client for any pufpose whatsoever. The Geetechnical Engineer will retain all pertinent records relating to the services pcrfortnod for a period of five (S) years foBowing submission of the report, during which period the records will be made available to the client at all reasonable times. Neither the client nor the Geoteclmical Engineer may delegate, assign, sublet or transfer his duties, data generated by this investigation, or interest in this Agreement without the written consent of the other party. Signature of Client responsible for payment of wodc performed by Cit of Coppell Client: Signature: / Date: DISPUTES In the event that a dispute should arise relating to the perfornmnce of the services to be provided under this Agreement, and should that dispute result in litigation, it is agreed that the prevailing party shall be entitled to recover all reasonable costs incurred in the defense of the claim, including staff time, court costs, attorneys' fees, and other claim-related expenses.