Loading...
Gateway BP(1.4)-CS 960801lI - ,,I Halff Associates ENGINEERS · ARCHITECTS · SCIENTISTS PLANNERS · SURVEYORS 08-02-96 8616 NORTHVJ/EST PLAZA DRIVE DALLAS, TE:~,S 75225 (214~'~39-0094 A10:54 IN F~ City of Coppell 255 Parkway Boulevard Coppell, Texas 75019 ATTN: Mr. Ken Griffin Assistant City Engineer RE: Lot 1R, Block 2 August 1, 1996 AVO 15315 ~t Gateway Business Park ~ ~'~ Paving, Drainage & Utility Improvements/. ~ / Dear Mr. Griffin: / 1 On behalf of Haverty Furniture CompanieS, Inc., we are requesting a variance to delete lime stabilization from the pavement sul~grade. We request approval for the subgrade in the drive and parking areas to be ~carified to a depth of 6 inches and recompacted in lieu of the city standard 6-inch lime~tabilized subgrade as follows: · For the parking areas we propose ~,_~-inch~ 3,000 ps~einforced concrete ~ pavement section on compacted subgrade to i'epla~e the city standard 5-inch 3,000 psi reinforced concrete pavement section on a 6-inch lime stabilized subgrade. For the loading dock areas and west side fire lane we propose a 7-inch 3,000 psi reinforced concrete paving section to replace the city standard 6-inch 3,000 psi reinforced concrete pavement section on a 6-inch lime stabilized subgrade. We have attached a signed and sealed letter of recommendation from the geotechnical engineer, Henley Johnston & Associates, Inc. If you have any questions or require any additional information, please do not hesitate to call either Pat Acker or myself. Sincerely, HALFF AS~ATES, INC. Ice Pr'~sident' ' cc: Charlie Schmidt, Haverty Furniture Companies, Inc. DALLAS · FORT WORTH · HOUSTON · ARLINGTON · McALLEN · CHICAGO TRANSPORTATION · WATER RESOURCES · LAND DEVELOPMENT · MUNICIPAL · ENVIRONMENTAL · STRUCTURAL MECHANICAL · ELECTRICAL ° SURVEYING · GEOGRAPHIC INFORMATION SYSTEMS ARCHITECTURE · LANDSCAPE ARCHITECTURE · PLANNING HENLEY JOHNSTON & ASSOCIATES, INC. engineering !~oscie~w¢ consul[an[$ JUL 3 J 7996 "'-. -* ,'-~,:b.~',,.5. IFIC 30 July 1996 Haverty Furniture Companies, Inc. 866 West Peachtree St. Atlanta, Georgia 30308 Attention: Mr. Charlie Schmidt Re: · Pavement Design Regional Distribution Center Dallas, Texas Dear Mr. Schmidt: As discussed last week, we have reviewed the pavement recommendations for the subject project. We recommend that the design of the pavement for the subject project be modified to include special treatment of the soil surface to allow for elimination of the 6-in. lime treated subgrade. We recommend that the subgrade in parking and drive areas be scarified to a depth of at least 6 inches, water added as needed, and this layer compacted to a dry density of 95 to 98 percent of the maximum dry density determined by ASTM D 698 at a moisture content between Optimum Moisture Content and four percentage points above Optimum Moisture Content determined by the same test. No leveling sand should be used under the pavement, and the soil sudace should be moist when concrete is placed. All joints must be sealed and the sealant maintained. We trust this provides the information you need at this time. Please call us if you have any questions or require additional information. :7,, .--'"," '..._'f'.,, ~! Very truly yours, /,-,....-' '-..?;,, ,.--O-- '~;~',,,:~!--c.!.S.'r~.'~&_-~? John W. Johnston. P.E. t~.~/OnXt_~: Henley-Johnston & Associates inc. JWJ CC: Cristina Gonzalez-Criado, E.I.T. Halff Associates, Inc. (214) 941-3808 fax 1214} 943-7645 235 *,Iorcan Ave.. Dallas l'e~-as 75203-1088