LOW PRESSURE AIR TEST FOR GRAVITY SANITARY SEWER
~est Procedure
Eac.~ '"", of
se~.,v.,'l sewer shall be tested between sucessive manholes.
A~r shah be m-',roduced into the pipeline until 4.0 psi gauge pressure has been reached.
A:. mat ~me me flow of air shall be reduced and the internal air pressure shall be maintained
c. er..veer: 3 5 and 4.5 psi gauge for at least two(2) minutes to allow the air temperature to come
.~ ~.4.~,,u.,~m with t,~e temperature of the pipe walls. Pressure in the pipe shall be constan!ly
mon;~,3reg Dy a gauge and hose arrangement separate from the hose used to introduce mr
;".e ,ne 2ressdre m the p:pe Shall nOt be allowed to exceed 5 psi.
'-.O,e~ the tempera(ute has stabilized and no air leaks at the plugs have been found, the air pressure
s,qa~! be used to determine the time lapse required for the air pressure to drop to 2.5 psi gauge
I! the time lapse required for the air pressure to decrease from 3.5 to 2.5 psi exceeds that shown
~r..e to~lo.c,.:nq fable, i:r~e p~pe shall be presumed to be within acceptable limits for ieakage
if i.:he hme !apsed is less man that shown in the table, the contractor shall make corrections to
reou-.:e t..",e :ea~age to acceptable limits.
Line Information ] I [Test Results lair Test [Mandrel
Line Stauon [o Static2 Pipe Size L.F.Tested Time Passed? Passed?
Owner I'"'"'~'~ ~O,~, Date
ProjectC~l~,:~'-;t O(((c.~_ Q.e,",~e~r ]N~.~,~. ~ Job#
Tested B'/
inspectors Full Name
~PROFESSIONAL INLINE
SERVICES, INC.
P.O. BOX 118095
CARROLLTON, TX 75011
(972)939-2600
LOG REPORT
11-17-2000
CONTRACTOR:TRI-DAL
INSPECTOR :LA_N-NY ALLISON
OPERATOR :RUBEN.R
CONT1LACT #:NONE
TAPE # :1
PAGE # :1
PIPE INFORMATION
MH STATION # :5+00
MH STATION # :5+56
PIPE TYPE :PVC
PIPE SIZE :8"
DIRECTION :UP
GRADE :0.40%
LINE # :A-STUBOUT
JOB NAME :GATEWAY
BUSINESS PARK NO.II
LOCATION :COPPELL,TX
CONDITION :NEW
FOOTAGE: TIME OF DAY: FAULT OR COMMENTS:
0.0 Ft 3:12pm LINE A
M.H STA.5+00
TO STUB-OUT
52.3 Ft 3:15pm STOPPED AT END OF
STUB-OUT AT STA.5+56
~PROFESSIONAL ~LINE
SERVICES, INC.
P.O. BOX 11~095
CARROLLTON, TX 75011
(972)939-2600
LOG REPORT
11-17-2000
CONTRACTOR:TRI-DAL
INSPECTOR :LANNY ALLISON
OPERATOR :RUBEN.R
CONTRACT #:NONE
TAPE # :1
PAGE # :2
PIPE INFORMATION
MH STATION # :5+00
MH STATION # :0+00
PIPE TYPE :PVC
PIPE SIZE :8"
DIRECTION :DS
GRADE :0.40%
LINE # :A
JOB NAME :GATEWAY
BUSINESS PARK NO.II
LOCATION :COPPELL,TX
CONDITION :NEW
FOOTAGE: TIME OF DAY: FAULT OR COMMENTS:
0.0 Ft 5:01pm LINE A
M.H STA. 5+00
485.8 Ft 5:20pm STOPPED AT M.H STA.0+00 END OF LINE A
END OF SURVEY