Loading...
Gateway BP(2.1)-CS 980119 ENGINEERS · .ARCHITECTS ' SCIENTISTS Janum' 19. 1998 "/ AVO 16763 Mr. Kenneth Griffin c/o Michael Martin City of Coppell 255 Parkway Boulevard ~,. P.O. Box 478 Coppell, Texas 75019-4409 Dear Mr. Griffin, Halff Associates, Inc. would like to submit an alternative pavement design for Gateway Business Park No. 2. For the parking area, the alternative design is 5 inch thick 4000 PSI compressive strength concrete with #3 bars, 18 inch O.C.E.W. on compacted subgrad, in lieu of the 5 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade as shown in Appendix C of the City of Coppell Subdivision Ordinance. For the fire lane, the alternative design is 6 inch thick 4000 PSI compressive strength concrete with #3 bars, 18 inch O.C.E.W. on compacted subgrade in lieu of the 6 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade showm in Appendix C of the City of Coppell Subdivision Ordinance. If you have any questions or require any additional information, please contact Pat Acker or myself. Sincerely, 6~~ HALFF ASSOCIATES, INC.~::::~ ~"" ~F'~'- tM. Todd Abbott cc: Steve Williamson Steve Brian Laurie Hodges Neil Harper DALLAS · FORT WORTH · HOUSTON · McALLEN TRANSPORTATION · WATER RESOURCES · LAND DEVELOPMENT · MUNICIPAL · ENVIRONMENTAL. STRUCTURAL MECHANICAL · ELECTRICAL · SURVEYING · GEOGRAPHIC INFORMATION SYSTEMS ARCHITECTURE · LANDSCAPE ARCHITECTURE · PLANNING