Gateway BP(1.3)-LR 990512CONTRA CT INSPECTION SER VICE, Inc.
4305 Glenwood Ct. Granbury, TX 76049 (817) 246.8096 FAX (817) 246-5889
REPORT OF
STRUCTURAL STEEL INSPECTION
Project:
Client:
Gateway I!
Coppell, TX
Reed Engineering
2424 Stutz, Suite 400
Dallas, TX 75235
Report No:- 13343-9
Attention: Keith Atkins
Date of Service: 5-12-99
Page 1 of 1
Drawings utilized:
REPORT OF INSPECTION
Structural
Locations/item inspected:
Roof level framing between lines A to J / 1 to 9
Discrepancies/comments:
*Roof level metal deck installation, numerous non-compliant puddle welds and side lap screw
locations were found throughout this area. All non-compliant locations and non-inspected
areas were marked accordingly with orange paint.
Randy Walcker CWI #97121591
Technician
f~ntract Inspection Service
This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client