Gateway BP(1.3)-LR 990512CONTRA CT INSPECTION SER VICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246.8096 FAX (817) 246-5889 REPORT OF STRUCTURAL STEEL INSPECTION Project: Client: Gateway I! Coppell, TX Reed Engineering 2424 Stutz, Suite 400 Dallas, TX 75235 Report No:- 13343-9 Attention: Keith Atkins Date of Service: 5-12-99 Page 1 of 1 Drawings utilized: REPORT OF INSPECTION Structural Locations/item inspected: Roof level framing between lines A to J / 1 to 9 Discrepancies/comments: *Roof level metal deck installation, numerous non-compliant puddle welds and side lap screw locations were found throughout this area. All non-compliant locations and non-inspected areas were marked accordingly with orange paint. Randy Walcker CWI #97121591 Technician f~ntract Inspection Service This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client