Gateway BP(1.3)-LR 990507CONTRA CT INSPECTION SER VICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889 REPORT OF STRUCTURAL STEEL INSPECTION Project: Client: Gateway Business Park Coppell, TX Reed Engineering Group 2424 Stutz, Suite 400 Dallas, TX 75235 Report No: 13287-9 Attention: Keith Atkins Date of Service: 5-7-99 Page 1 of I Drawings utilized: Locations/item inspected: REPORT OF INSPECTION Structural Roof level framing, between line A to G / I to 9 Discrepancies/comments: * 1 .) Column anchor bolts, some loose nuts found along line 2 and other areas under water. 2.) Joist seat welds determined to be compliant. *3.) Joist bridging not complete at side walls. *4.) Joist seat lug support attachments along line 1, welds not complete at bottom leg to embed plate. * 5.) Double angle over column at joists, installation not complete. * Discrepancies Randy Walcker CWI #97121591 ~~'~ ~-C"ontract Inspection Service Technician This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client