Gateway BP(2.1)-LR 981001 (3) aafnep, rJnu ca.
9200 King Arthur Drive
Dallas, Texas 75247-3610
Phone 214/631-4372 Fax 214/631-4380
Mr. Robert McCann Project No.: 1598-0007
Catellus Development Corp. Project: Lucent Technologies I
4545 Fuller Dr., Suite 100 Location: Over Excavated Subgrade West Parking Area
Irving, Texas 75038 Report No.: 117
RESULTS OF FI-FLD DENSITY TESTS
'-'. cds'" :;A'[':'£ RETEST ';'ES'I' LOCATION LII'-I-. PROCTOR FIELD FIELD PERCENT
:',~;' OF DEPTH TEST DENSITY .MOISTURE OF
TEST NO PCF ~ o SPECIEIED
NUMBER COMPACIION
112 10/01/98 100' S and 25' W of NW Corner of Building 6 SG 2 89.2 26.1 96.4
113 10/01/98 100' S and 75' W of NW Corner of Building 6 SG I 95.9 24.2 97.6
114 10/01/98 50' S and 25' W of NW Corner o£Building 6 SG I 93.6 23.6 95.3
115 10/01/98 50' S and 25' W ofNW Corncr of Building 6 SG 2 93.4 26.8 100.9
116 10/01/98 25' S and 25' W of NW Corner of Building 6 SG 2 88.6 26.1 95.8
117 10/01/98 25' S and 175' W of NW Corner of Building 6 SG 2 90.9 27.0 98.3
TESTS PERFORN, flr.,D BY: Jolm Morelm~d TEST METHODS: ASTM D 2922, D 3017, D 1558, D2167 OR D 2937
R.EN.L, LRKS:
I~ROCTOR NO.: #l - 98.2 pcf(~ 22.9% moisture
~2 - 92.8 pcf'~ 25.6% moisture
I)ISTRII3UTION: Cadence McShane
GDA, Scott McCreary
I Iavncs Whaley - Mark Thompson
City of Coppell - Garreth Campbell
PAGE 1 OF I