Gateway BP(2.5)-LR 990105 (06) Information
BuiM On
Engineering · Consulting · Testing
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
DATE:
ALAN GRIMES
ROGERS O'BRIEN CONSTRUCTION
11145 MORRISON LANE
DALLAS, TX 75229
January 05, 1999
PROJECT: G & K LAUNDRY
REVISION
OUR REPORTNO.:337-80080-69
PROCESSING
FIELD DATA:
LOCATION OFPLACEMENT
EAST SIDE PAVING
RIGHT END, 5'
DATE PLACED December 29, 1998 SUPPLIER LATTIMORE
TIME 12: 40 pm DELIVERY TICKET NO./TRUCK NO. 6086747
SLUMP, IN. 5 MIX NUMBER AND PROPORTIONS 42
AIR CONTENT, % _ _ - CEMENT - - -
AIR TEMPERATURE, o F 55 WATER - - -
CONCRETE TEMPERATURE, °F 57 FINE AGGREGATE - - -
DATE RECEIVED IN LAB December 30, 1998 COARSE AGGREGATE - - -
FIELD DATA SUBMITTED BY PS I \R. BURTSELL ADMIXTURE - - -
MIX DATA SUBMITTED BY LATTIMORE
SPECIMEN ITEST
LABORATORY IDENTIFICATIONAGE
NUMBER, OR SETNO, (DAYS)
1139 7
1139 28
1139 C 28
1139 D 'H
COMPRESSION TEST RESULTS
ASTM C39-96
~ - - [- T;~'AJ ' CYLINDER CYLINDER ~OMPRESSIVE
DATE OF / LOAD DIA(iMNE.~ER AREA STRENGTH
TEST / (LBS.) (SQ, IN.)i(PSI)
01/05/99 125500 6.00 28.27 4440
01/26/99 140000 6.00 28.27 4950
01/26/99 145000 6.00 28 27 5130
HOLD 6 . 00 28 27
SPECIFICATIONS 0
REMARKS:
~PE OF BREAK
Cone
Cone
Test results comply wilh applicable
Cylinders picked up by PSI
X Cylinders made by PSI representative. X representative. X specifications.
Cylinders made by Architect's or Test resulls do not comply with
Contractor's representalive. Cylinders delivered to PSI laboratory, applicable specificalions.
TECHNICIAN: R. BURTSELL
cc: (1) ROGERS O'BRIEN (1) HALFF ASSOCIATES, INC.
(1) CITY OF COPPELL Attn:GARRETH CAMPBELL
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REI~)RTS MAY NOT BE REPROOUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC.
Respectfully submitted,
Professional Service Industries, Inc.
Professional Service Industries, Inc.. 2556 Gravel Drive · Fort Worth, TX 76118 · Phone 817/284-3783 · Fax 817/284-8942