Loading...
WA9302-LR 960404 (4) '-' 7 'EOTECHNICAL E GEE Consultants, Inc. E] NVIRONMENTAL 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 lIEPORT OF CONCRETE MIX INSPECTION lleFort Date: April 4, 1996 Date Concrete Placed: February 21, 1996 Standard 6"x12" (2 lit'l/l: City of Coppell Area 28.27 Square Inches P 'o~cct: 6.0 Million Gallon Water Storage Tank Concrete Report No.: 146 C .H~tl'itctol-: Natgun Coloration Project No.: 95-0196 L ,H;c~ctc Supt~iicr ;tlld lqai,. RcdiMix Concrete - Plant ffl [ OCatiOll Of Placement: Wall Slots MATERIALS ~"""~" ";"~" ~"~ INSPECTION DATA 1 )csc :ipl lob ~ I hs/Cu. Yd ~ N[b Number: 689 Time Sample Batched: 2:I0 pm Cement: Time Sampled: 2:30 pm ~ly Ash: Sample Location: ~16-22 Truck/Ticket No: t70/10417 C oa rse Aggregate: Temperatu re: [,termedinto Aggregate: Ambient Range: 93¢F Fillc Aggregate: Concrete Range: 81~F fi d~nixtures: Slump Range (inches): 7V2" Weather Conditions: Clear Time Started: 10:30 am ' Time Completed: 4:15 pm fi dded Water: 25 gal. Sample Air Content (%): Total Cubic Yards Placed: 23.0 C.Y. Required Strength (Lbs./sq.in.): 5.000 psi %pCCtlIlCtl MCiI,LIICt[ Age Date '['ot;ll Load Conlprcssivc Strength Remarks Number Sltun]~ ~lui tDaysl Tested (Lbs.t (Lhs./Sq.hl.) CWT 500 7 V2" 7 02/28/06 191,720 6.760 CWT 501 7 ~/}" 28 03/20/96 I 191,280' 6,770* CWT 502 7 %" 28 03/20/96 191,640' 6,780* 'c,t Melht~ls HHlized }:/aCltlR' Reguktr kSI'M C 3hC 39,C 14~ tinless Noted Otherwise) Cylinders Made By: S.J. _ g eraarks and/or Distribution: Slump was 1" before super was added. *Tests were not cart'led out until hilure. c: Mr I.arry Davis city lit' Cuppell Mr. Gal3 lIcndz lci<:; Shimcl<...]acobs and Fmklea