Loading...
Gateway BP(1.2)-LR 990707TECHNOLOGIES INC Maxim Technologies Inc. 2575 Lone Star Drive Dallas, Texas 75222 Telephone: {214) 831-2700 FAX: (214) 920-1891 CLIENT: PROJECT: SERVICES: REPORT OF CONCRETE COMPRESSIVE STRENGTH ABCON CONSTRUCTION Attn: Rusty Whitaker 1045 E. HWY 121 Lewisville, TX 75057 Pavement Renovation -Coppell Texas, Various GATEWAY & FRITZ PAGE 1 OF 1 PROJECT NO.: 9710310 REPORT NO,: 148223 DATE OF SERVICE: 6/09/99 AUTHORIZATION: Rusty REPORT DATE: 7/07/99 Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: ABCON CONTRUCTION CONCRETE SUPPLIER: Custom Crete PLANT: NA SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 7" maximum AIR: NA METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ~'~v[ C143 TEMPERATURE: ~,~v[ C1064 AIR CONTENT: ~S~,[ C173 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C1231 TESTING: ~S~v[ C39 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED {days) {in.) {sq.in.) {lbs. force~ (psi) FRACTURE TYPE 1 1 6/16/99 7 6.00 28.27 80710 2850 UNBONDED CAP 1 2 6/16/99 ? 6. O0 28.27 83590 2960 LTNBONDED CAP 1 3 7/07/99 28 6.00 28.27 129550 4580 LTNBONDED CAP 1 4 7/07/99 28 6.00 28.27 126070 4460 UNBONDED CAP PROJECT DATA CLASS OF CONCRETE: 4050A DATE OF PLACEMENT: 6/09/99 TIME SAMPLED: 11: 0SAM BY: Lloyd Burtsell TEMPERATURE {DegF) - AIR: 82 CONCRETE: 86 TRUCK NO: 464 TICKET NO: 173610 MEASURED SLUMP (in.): 4.50 AIR CONTENT(%}: 1.7 UNIT WEIGHT{pcf): NA LOCATION OF PLACEMENT: 10' east from west end of pour 15' north REMARKS Technician: Lloyd Burtsell Started: 10: 00AM Stopped: 12:30PM Report Distribution: (1) ABCON CONSTRUCTION (1) City of Coppell MAXIM TECHNOLOGIES INC. Our letters and reports are for the exclusive use of the client to whom they are edd. ressed an~. shall not be. reEred.uced except in full without the approval of the testing laboratory. The use of o~..r .n~ne must recmv.e our ,wrnten appr .o~vm:. u.ur mt~er..s aha re. ports 1001 PH apply only to the semple tested and/or inspected, and are not ~nd~ca/Jve of the quantities or apparently toermca~ or s~m~mr prouucts.