Gateway BP(1.2)-LR 961008 (2)IN-PLACE DENSITY t STING
4747 Irvh~g Blvd., Suite #206
Dallaa, Texan 75247
Date of Service:
Client No.:
Client:
Services:
10/08/1996
13195OOO
Catellus Development Corporation
Mr. Steve Williamson
4545 Fuller Drive, Suite 100
Irving TX 75038
In-place density testing.
Report No.: 9611226
Project No.: 43-1452-96
Project: Fritz Gateway-Warehouse
LBJ ~ Cotton & Gateway
CONTRACTOR:
PROJECT DATA
Laboratory Test Method:
ASTM D-698
Field Test Method:
MOISTURE DENSITY RELATIONS:
M/D No. Description
1 Dark Brown Clay
2 Dark/Medium Brown/Tan Clay
Moisture
maximunl
Density pcf
26.0 95.5
24.3 96.3
FIELD DENSITY TESTS
ASTM D-2922
ASTM D-3017
Project Requirements
Moisture Density
-2 to +4% 95.0%
-2 to +4% 95.0%
TEST
NO
581
582
583
TEST LOCATION
M/D MOISTURE DRY DENSITY DENSITY
No. (%) (pc0 (% max)
Paving area, subgrade, 690N/125W '
Paving area, subgrade, 800N/125W
Paving area, subgrade, 890N/125W
1 27.4 92.4 97
1 27.0 93.0 97
1 27.1 92.7 97
Test results on this report meet project specification.
Technician: Jesse Landreth
Report Distribution:
(1) Catellus Development Corporation
(1) Crromatzky Dupree & Associates
(1) Brockette-Davis-Drake, Inc.
(2) Haws & Tingle
07AS
(2) City of Coppell
(1) Abbott Development
E~~ Inc.
Paul D. Smith, P.E.
Senior Project Engineer
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, tnc~