Gateway BP(2.1)-LR 980317 (2) Engineering I:n.
9200 King Arthur Drive
Dallas, Texas 75247-3610
Phone 214/631-4372 Fax 214/631-4380
March 17, 1998
Mr. James T. McLaughlin PROJ£¢T Lucent Technologies
Catellus Development Corporation Coppell, Texas
4545 Fuller Drive, S-100 LOCATION Parking Area Fill
Irving, TX 75038
RSPORTNO. 5 ST Job NO. 1598-0007
RESULTS OF FIELD DENSITY TESTS
RETEST
TEST DATE CF COMPAC-~ON :iELD ~IE_D OF
',O TEST -EST LOCAT C'% TEST ** DENSITY MOIS-UFE SFECi=~ED
NUMBER NO. PCF :.:
Lift
22 3/12/9E~ - 30' S., 40' :E. o:f S/W 1 1 96.2 24.4 98.0
COT. of Bldg.
23 " - 45' S., 120' E. of S/W 1 1 93.4 25.9 95.2
CoT. of Bldg.
24 " - 35' S. , 185' E. of S/W 1 2 91 .7 29.0*** 99.1
CoT. of Bldg.
25 " - 45' S., 240' E. of S/W 1 2 90.1 30.8*** 97.4
CoT. of Bldg.
26 " - 40' S., 380' E. of S/W 1 2 90.2 27.6 97.5
CoT. of Bldg.
TESTS PERFOqMED BY: J. Moreland, C.E. T. TEST METHODS: ASTM D 2922. D 3C'7. D :556 D 2'67
OR D 2~37
REMADKS ** Test No. 1: 98.2 pcf @ 22.9% moisture.
Test No. 1: 92.5 Dcf @ 25.6% mois~re
*** Reco~end Pass.
~k~.~& ...~_1~
Cadence McShane Z [yN~NJa%.~
~_..---..----~T~
G DA - Scott McCreary
~a~es ~aley - Mark Thompson
~ity of Coppell - Garreth Campbell.