Gateway BP(1.2)-LR 960822IN-PLACE DENSITY TESTING Date of Service: Client No.: Client: Services: 08/22/1996 13195000 Catellus Development Corporation Mr. Steve Williamson 4545 Fuller Drive, Suite 100 Irving TX 75038 4747 Irving Blvd., Suite #206 Dallas, Te.x~ 75147 Report No.: 9608369 Project No.: 43-1452-96 Project: Fritz Gateway-Warehous~ LBJ ~ Cotton & Crateway cowrgAcroR: Superior Utilities PROJECT DATA I~bor~toryr~tM~aoa: ASTM D-698 Field Te~t Method: MOISTURE DENSITY RELATIONS: M/D No. 1 Dark/Med Brown/Tan Clay Maximum Moisture % Denny pcf 24.3 96.3 FIELD DENSITY TESTS ASTM D-2922 ASTM D-3017 Project Requiremmts Moisture Demlty -2/+4% 95% NO 538 539 540 TEST LOCATION 8th lite, sm. 0+25, 66" RCP 8th lift, sta. 2+50, 60" RCP 8th li~ sta. 4+60, 60" RCP M/D MOISTURE DRY DENSITY DENSITY No. ('/.) (W0 (./. m~) East drainage easement, 1 25.0 93.7 97.3 1 24.6 94.2 97.8 1 24.9 93.9 97.5 Test results on this report meet project specification. line A, storm sewer. Technician: Jesse Landreth Report Distribution: (1) Catellus Development Corporation (I) Gromatzky Duprce & Associate~ (1) Brocketto-Davis-Drake, Inc. (2) Haws & Tingle (2) City of Coppell ( 1 ) Abbott Development H~~ng, Inc. Paul D. Smith, P.E. Senior Project Engineer fi/CC This report is exclusively for the use of the client indicated above and shall not be reproduced except in full wflhout ~he written approval of HBC Engineering, Inc. IN-PLACE DENSITY TESTING 4747 Irving Blvd., Suite #206 D~,na~ Texas 75247 Date of Service: 08/21/1996 Client No.: 13195000 Client: Catellus Development Corporation Mr. Steve Williamson 4545 Fuller Drive, Suite 100 Irving TX 75038 Services: In-place density testing. Report No.: 9608298 Project No.: 43-1452-96 Project: Fritz Cratcway-Warehouse LBJ ~ Cotton & Gateway CON'nO, CTOR: Superior Utilities PROJECT DATA Laboratory T~t Mtqimd: Field Test Method: MOISTURE DENSITY RELATIONS: MID No. Description Moisture % DemiOd 1~' 1 Dark Brown Clay 26.0 95.5 FIELD DENSITY TESTS TEST MID MOISTtlRE NO TEST LOCATION No. (%) 535 7th li~ sra. 1+00, 66" RCP 1 26.8 536 7th lift, sra. 3+00, 60" RCP 1 27.0 537 7th lii~, sta. 5+00, 60" RCP 1 27.4 Test results on this report meet project specification. East drainage easement, line A, storm sewer. Project Requirements Moisture Density -2~4% 95% DRY DENSITY DENSITY (pcO (% ,,,,x) 93.3 97.7 93.0 97.4 92.6 97.0 Technician: Jesse Landreth Report Distribution: (1) Catellus Development Corporation (1) Ca, omatzky Dupree & Associates (1) Brookotte-Davis-Drake, Inc. (2) Haws & Tingle (2) City of Coppell (1) Abbott Development Inc. Paul D. Smith, P.E. Senior Project Engineer 07CC This report is exclusively for the us~ of the client indicated above and shall not bo reproduced except in full without the written approval of HBC Engineering, Inc.