Gateway BP(1.2)-LR 960726 (3) IN-PLACE DENSITY STING 4747 Irving Blvd., Suite #206 Dallas, Texas 75247 Date of Service: Client No.: Client: Services: 07/26/1996 13195000 Catellus Development Corporation Mr. Steve Williamson 4545 Fuller Drive, Suite 100 Irving TX 75038 h-place density testing. co~rr~croR: Haws & Tingle MOISTURE DENSITY RELATIONS: Report No.: 9606641 Project No.: 43-1452 Project: Fritz Ga Lm PROJECT DATA Laboratory Te~t Method: AST~ Field Te~t Method: M/D No. Description Moisture % Density pcf 1 Tanni~h Brown Sandy Clay W/CB 13.0 119.5 2 Dark Brown Clay 26.0 95.5 3 Dk/Md Bm/Tn Cly W/Rddsh Brown 21.0 104.0 ASTM ASTM FIELD DENSITY TESTS TEST M/D MOISTURI~ NO TEST LOCATION No. (%) -96 ~oway-Warehouse 2otWn & Gateway D-698 D-2922 D-3017 Project Requirementa Mohtur* D~mlty ~+2% 95% 1-2/+4% 95% -2/+4% 95% 426 3rd lift, grid 1370 ft. n., 210 ft. e. 1 13.9 427 3rd lffi, grid 1370 ft. n., 300 ft. e. 1 14.2 428 3rd lift, grid 1370 ft. n., 380 ft. e. 1 14.0 429 2nd lift, grid 1460 f~. n., 150 ft. e. 2 27.4 430 2nd lift, grid 1450 ft. n., 225 ft. e. 2 27.1 431 2nd lift, grid 1470 ft. n., 320 ft. e. 2 27.9 432 2nd li~ grid 1450 ft. n., 425 ft. e. 3 22.6 433 2nd lit~ grid 1460 ft. n., 500 ft. e. 3 22.1 434 3rd lift, grid 1470 ft. n., 100 ft. e. 3 23.0 435 3rd li~ grid 1460 ft. n., 200 ft. e. 3 22.5 DRY DENSITY DENSITY 117.2 98.1 116.7 97.7 116.9 97.8 93.1 97.5 93.6 98.0 92.3 96.6 100.9 97.0 101.5 97.6 100.4 96.5 101.1 97.2 07CC This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering Inc. Report No.: 9606641 (~ Page2 '~ ' TEST NO TEST LOCATION M/I) MOISTURE ~o. (./,) 2 27.4 2 27.6 3 22.0 436 3rd lift, grid 1450 ft. n., 300 fi. c. 437 3rd lii~ grid 1460 ft. n., 400 ft. c. 438 3rd lift, grid 1470 ft. n., 50 ft. c. Test r~ults on this repo~ meet project specification. Test numbers 426 thru 428, building pad. Test numbers 429 thru 438, paving area at east end along temporary d DRY DENSITY (l~0 93.0 92.7 101.5 :ainage easement. DENS,fY (%m~) 97.4 97.1 97.6 Technician: Jesse Landreth Report Distribution: (1) Catullus Developmem Corporation (1) Groma~'y Dupr~ & Associates (1) Brock~tt~-Davis-Drake, lno. (~) rhws & Tingl, (2) City of Coppoll (1) Abbott Development D. Smitl~ P.E. Senior Project Engineer Inc. 07CC This report is exclusively for the use of thc client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.