Loading...
Gateway BP(2.4)-CS 990105/_--~ The City With A Beautiful Future ~ RO. BOX 478 COPPELL, TEXAS 75019 PO, Box 478 Coppell, Texas 75019 972-462-OO22 January 5, 1999 Mr. Patrick Acker, P.E. Halff Associates 8616 Northwest Plaza Dr. Dallas, TX 75225 RE: Gateway Business Park No. II, Lot 2, BlockI~ Dear Mr. Acker: The City of Coppell has reviewed the referenced plans and has the following comments to offer: 6. 7. 8. On all sheets, show construction of a left turn lane from southbound Freeport Parkway into Dividend Drive. Change "Preliminary Plat" to "Final Plat." The minimum driveway spacing for a 35mph roadway is 100'. Please note on the plans that the paving treatment in Dividend Drive 'will be maintained by the property owners association via a right-of-way use agreement.. Reference the variance request letter in your concrete design legend. All storm drain pipe size changes require a concrete collar. Provide a 20'x20' easement around each fire vault. All fire hydrant locations need to be approved by the City Fire Marshall, Travis Crump. He can be reached at (972)304-3503. Provide a storm drain manhole at the location specified on the marked plans. Sincerely, Kent M. Collins, E.I.T. Graduate Engineer