Loading...
WA9302-LR 960131Division of Wire Rope corporation ~f America, Incorporated 601 Cctpa-~ Driv~*Chillic~e~, MO 64601'(816)646-3572 WRCA Certificate of Compliance REPORT OF CHEMICAL ANAYLYSIS AND PHYSICAL TESTS Date 1/31 Customer Natgun CorpQ.ration Ship To Natgun Corporation Address 11 Teal Rd. Site of New Water Tank Wakefield, MA 81880 Coppell, 'rX 75019 Mill Order No. See Below Customer Order No. 7336 Ship Date 1/31/96 1 00% Domestic Material item Description Tensile Weight Red. of Torsion Elong. - Number Lbs. PSI oz/sq.~. Area % Test 12" 1 .192 Tank Wrapping Wire ASTM A821-93 ~ 9500461 -3 0.1937 6870 233,135 24 2 Coils, 2,048 Ibs. net 9500462 -6 0.1933 6901 2357157 22 -8 0.1932 6790 231,614 22 12 Coils, 12,019 Ibs. net 9500463 -39 0.1933 6870] 234,1011 22 2 Coils, 1,981 Ibs. net Heat No. 44221 C .71 Mn .67 P .006 S .008 Si .24 9500464 -5 0.1935 6900 234,637 23 -25 0.1933 6860 233,760 23 -35 0.1937 6770 229,742 22 28 Coils, 27,872 Ibs. net Heat No. 449:>~ C .72 Mn .65 P .004 S .009 ;Si .25 TOTAL 44 Coils, 43,920. Ibs. net The matedal covered by this certification was manufactured and tested in accordance with specifications as listed above. We cerdfy that representative samples of the matedal have been tested and the results conform to the requirements outlined in these specifications. The Chemical, Physical, or Mechanical tests reported above are correct as contained in the records of the corporation. By ~Metallurgy/QA L~ REJECTED ~ REVISE AND RESUBMIT ~ SUBMIT SPECIFIED ITEM Ch~,:~<f,3'~ ~s en~y for g~r:eTsl conformance with the design ccmc..:~: :-~ '".~: ~L,r.?.:~ ':~;~C'~ ~:~;~:;~L COR1D~RGe W:,~h the irffc::~'~<~rs F:L:"'-:;~ E~-~ L:-~ c~:L:;-~,::: C~goEr~:~ff~t% Ar:~ aCt~OR shc;w:~ iz.: ~:?.~;c, ct to Lh~ ro:]L/h'oR~3'~2s c~2 the pians and wh~:~, ,~H~i ~:~e conF~r~':2d a~d ~::~:r;~:~'c.d ~L '2'J~ ~eb site; fabr~catic;~ p~oce.~xs,:? ~:nd ¢~c~q~es of co:~s. Lruct~,-m, co- Ordination of [~is w3~'[< wE~,~ C~::~t c~ aji sahe~ trades and ~orming his work in a safe .a~,d sa[is%c:Lcry manner. SHIMEK, JACOSS & I:iN1<LEA CONSULTING ENGINEERS DALES, TEXAS WRCA WIRE ,,Division of Wire Rope Corporation of America, Incorporated 601 Coqxr~ Driv~~ MO 64601'(816)646-3572 WRCA Certificate of Compliance REPORT OF CHEMICAL ANAYLYSI$ AND PHYSICAL TESTS Date 1/31/96 Customer IqatOun Corporation Ship To NatOun Corporation Address 11 Teal Rd. Site of New Water Tank Wakefield, MA 01880 Coppell, TX 75019 Mill Order No. 9500463 Customer Order No. 7336 Ship Date ~/3~/96 t 00% Domestic Material Item Description Tensile Weight Red. of TorsiOn Elong. Number Lbs. PSI oz/sq.fi. Area % Test 12" 1 .192 Tank Wrapping Wire ASTM ~,821-93 9500463 -1 0.1936 6720 228,280 21 -10 0.1936 6820 231,677 21 -20 0.194 6910 233,768 21! -30 0.1932 6880 234,684 21' -45 0.1933 6830' 232,738~ 20 '4-4 Coils, 42,767 Ibs. net Heat No. 44221 C .71 Mn .67 P .006 S .008 Si .24 The matedal covered by this certification was manufactured and tested in accordance with specifications as listed above. We certify that representative samples of the matedal have been tested and the results conform to the requirements outlined in these specifications. The Chemical, Physical, or Mechanical tests reported above are correct as contained in the records of the corporation. By ~ Mz~ager of Metallurgy/QA ~O EXCEPTION TAKEN [] MAKE CORRECTIONS NO1 ED , [] REJECTED [] REVISE AND RESUBMIT [] SUBMIT SPECIFIED ITEM Chec!',in~ is o~fiy fi-r F-:~'::icrat cc,:f,::,rmance with tile design iil~:::rn!:'.'.'.'.Torl ;/iv{'.n T:! ~:v: ,:'.Fj',::t~ :3C!',:"~':li s, A:J action sh,3',,~'p is c-~.!':,]e::ct to the r,e~_:r:;,.cr,.!,,!;t:~ c~~ the pbns and so~.:.-: .,-{' .,': C;:n'~:!'scter is ,~os:~,:~:~l~.'.~e ';or: di'.;~ensions , Tabricc:'.'jl:n p;cc:~::s2s, and t,~ch, j;ziues of ~o!'~sL'dc'~;.'..i'h co- crdinafion cf hZs we;V, ,,,,~!%h ti:gt oJ; all other trades and performing his w,,gk in a safe.; arid sat[sfactc, ry manner. i\l K L SHtK/~EK, jACOB$ & Fi,, EA CONSULTING ENGINEERS DALES, TEXAS o~t~ 2- ~°) -~)U .y