Latter-day-CS 950310The City With A Beautiful Future
March 10, 1995
P. O, Box 478
Coppell, Texas 75019
214 - 462-0022
FAX 214 - 393°0948
Sam Cardwell
W.B. Kibler
615 N. MacArthur
Coppell, Texas 75019
RE: 2" Irrigation Service for Median Adjacent to the Church of
Latter Day Saints Project
Dear Mr. Cardwell:
Per our discussion this morning I am sending this letter to
inform you of the city's requirements for water services under
pavement. The above referenced service line was damaged during
pavement construction for the Latter Day Saints project. During
the repair it was discovered that the service line was too
shallow and that the repair itself would be under newly poured
concrete.
The city's current standard is that no fittings on a copper
service line be allowed under street paving; therefore, you are
required to 1). re-bore and lower the service line to at least
18" below subgrade of pavement, and 2). the new service line must
be one full length of copper with no connections from the water
main to one foot outside back of curb, in the median where water
meter is located.
By copy of this letter I am informing our Construction Inspector
Larry Davis that this request has been made.
h.~e any ,
~ ~21~~~stions regarding this matter please contact
~ncerel~ !\ /1/ ~
~£ties Superin~dent
HLP/dg
cc: Larry Davis, Construction Inspector