Loading...
Lam Lee Add-LR000223DRILLED PIER INSPECTION REPOR'I ..... CLIENT: Alice Lee c/o Realty Capital Corporation BEARING STRATUM: Gray Shale PROJECT: Lam Lee DRILLING CONTRACTOR: D.D. Denman REPORT NO.: 00-014.142 REPORT DATE: 02-23-00 WO-1325 WO DATE: 02-18-00 TECHNICIAN: D. Rogers Pier lden~ca~ 1 Date Drilling Started 02-18-00 02-18-00 02-18-00 02-18-00 Date Ddlling Completed 02-18-00 02-18-00 02-18-00 02-18-00 Date Concrete Placed 02-18-00 02-18-00 02-18-00 02-18-00 Shaft Diameter (in.)- Designed/Measured 30 30 30 30 Bell Diameter (in.) - Designed/Measured N/A N/A N/A N/A Elevation of Pier form Ground Surface (ft.) N/A N/A N/A N/A Elevation to Top of Pier (ff.) 517,0 517.0 517.0 517.0 Depth to Bearing Stratum (ft.) 28.0 27.8 27.4 27.0 Depth of Bottom of Pier (ft.) 30.2 29.8 29.8 30.0 Penetration (ft.) - Designed/Measured 2.0/2.2 2.0~2.0 2.0~2.4 2.0/3.0 Length of Pier (ft.) 30.1 29.7 29.7 29.9 Casing Required: Yes/No Yes Yes Yes Yes Condition of Pier Bottom: WetJDry/Clean Dry Dry Dry Dry Plumb within vertical alignment: Yes/No Yes Yes Yes Yes Reinforcing Horizontal Alignment N/A N/A N/A N/A Vertical Bars: No. & Size 4-~ 4-#6 4-#6 4-#6 Horizontal Ties: Size & Spacing #3@12 #3@12 #3@12 #3@12 Cage Diameter (in.) 12 12 12 12 Length of Cage (ft.) 29.6 29.1 ' 29.1 29.3 Vertical Bars Spliced: Yes/No No No No No Concre~ Placed with Tremie: Yes/ho No No No No SOILTECI~I ENGINEER~.~ID TECT~IG, INC~ J~. Perdue Construction Material Testing Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro ° 817.595.0708 fax