Lam Lee Add-LR000301 (2) CONCRETE INSPECTION AND COMPRESSION TEST REPORT Client Alice Lee c/oRealty Capital Corporation Work Order Numbe 00-1351 Project 00-014 Lam Lee pg 1 of 2 Report Numbe 00-014.152 SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Psi ~ 28 days Date of Placement: 3/1/00 Slump(in.): 4-6 !Sampled by: D C Rogers Air Content(%): Weather: Cloudy and warm Concrete Temp(F): 100° iSupplier/Mix: Pioneer FIELD DATA SET # 1 Ticket #: 474241 Time Batched: 3:50:00 AM Time Sampled: 4:15:00 AM Slump (in.): 5 A r Content: Unit Weight (pcf): Concrete Temp(F): -- 60° Air Temp (F): 55° Yardage: 30 Location/Remarks: Building Slab - 5' west of D-12 SET CYLINDER DATE AGE MAX LOAD '.STRENGTH TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT SOURCE 1 O1 3~8~00 7 106000 3750 1 02 3~29~00 28 142000 5022 ................ 1 03 3~29~00 28 139000 4920 1 04 Hold FIELD DATA SET #2 5:57:00 AM Time Sampled: 6:57:00 AM Ticket #: 474257 ,Time Batched: Slump (in.): 6 Air Content: Unit Weight (pcf): Concrete Temp(F): 60-; ...... Air Temp (F): 55° Yardage: 190 Location/Remarks: Building Slab 10' east of D-9 ........................................................... SET CYLINDER DATE AGE MAX LOAD ,STRENGTH, TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT SOURCE '2 0~_ ..... 31__81_0_0~_ 7_ _ 9-600-0- ..... --34---0-0~ 2 02 3~29~00 28 ].37000 4850 2 ' -53 - -372-9/-0% --- -28-- ' :1.~70~)0- .... 4~-~6 2 04 Hold ~,NORMAL CYLINDER SIZE 5X12, AREA:28,27sq. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS CO~PLY WtTH PROJECT SPECIFICATIONS UNLESS INDICATED "NON-COMPLIANCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231. C~'LINDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM SOILTECH ENGINE~ING AND TESTING, INC. -~neral Manager 2502 Gravel Drive · Fort Worth, Texas 76118 ° 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax CONCRETE INSPECTION AND COMPRESSION TE T REPORT Client Alice Lee c/oRealty Capital Corporation Work Order Numbe 00-1381 Project 00-014 Lam Lee pg 2 of 2 Report Numbe 00-014.152 SPECIFICATIONS PROJECT DATA Strength (psi): :4000 Psi ,Date of Placement: 3/1/00 Slump(in.): 4-6 Sampled by: D C Rogers Air Content(%): iWeather: ....... Cloudy and Warm Concrete Temp(F): :100° ;.Supplier/Mix: Pioneer FIELD DATA SET #3 Ticket #: 474279 Time Batched: 8:20:00 AM Time Sampled: 8:57:00 AM Slump (in.): 5 Air Content: Unit Weight (pcf): 0 Concrete Temp(F): 61 ° Air Temp (F): Yardage: 390 Location/Remarks: iBuilding slab SET CYLINDER DATE AGE MAX LOAD STRENGTH. TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT ' SOURCE 3 01 3/8/00 7 103000 3460 ; 3 02 3/29/00 28 141000 4990 3 03 3/29/00 28 139000 4920 3 04 Hold FIELD DATA SET #4 Ticket #: i 474287 Time Batched: 9:05:00 AM Time Sampled: 10:00:00 AM Slump (in.): 5 Air Content: Unit Weight (pcf): 0 Concrete Temp(F): 60° Air Temp (F): 60° Yardage: 450 Location/Remarks: Building Slab 8' east of D-4 SET CYLINDER DATE AGE MAX LOAD STRENGTH TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT SOURCE 4 01 3/8/00 7 109000 3860 4 02 3/29/00 28 140000 4950 4 03 3/29/00 28 134000 4740 4 04 Hold NORMAL CYLINDER SIZE: 5X12, AREA:28.27~I. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY WiTH PROJECT SPECIFICATIONS UNLESS INDICATED 'I~ON-COMPLIANCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231. CYLINDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ABTM 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax