Lam Lee Add-LR000817 (2) CONCRETE INSPECTION AND COMPRESSION TEST REPORT
Client: Alice Lee c/oRealty Capital Corp. Work Order Number: 00-2426
Project: 00-014 Lam Lee Report Number: 00.0~[4.248
SPECIFICATIONS PROJECT DATA
Strength (psi): :3000 PSi (~ 28 DAYS iDate of Placement: 8/17100
Slump(in.): 4"-6" iSampled by: Contractor Made
Air Content(%): N/A !Weather. !Warm/Humid
Concrete Temp(F): Not to exceed 90 degree 'Supplier/Mix: !Pioneer
FIELD DATA SET # 1
Ticket #: i N/A Time Batched: [ ~Time sampled:
Slump (in.): N/A [Air Content· ! N/A jUnit Weight (pcf): ~ N/A
Concrete Temp(F): N/A Air Temp (F): N/A !Yardage:
Location/Remarks: iLight Pole Standards South Side of Parking Lot
SET CYLINDER, DATE AGE MAX LOAD !STRENGTHi TEST CYLINDER NOTES
NO. NO. ';TESTED (days) (lbs) I (psi) I RESULT SOURCE
i ~ 01 18/24/001 7 75000 i 2650
i 02 19/14/00 28
1 03 9/14/00 28 '
]. 04 0/12/0 Hold
NORMAL CYLINDER SIZE: 5X12, ARF_~28.27sq. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY
WITH PROJECT SPECIFICATIONS UNLESS INDICATED 'I~0N-C0MPLIANCE" IN NOTES. FIELD TESTS BY S01LTECH ENGINEERING AND TESTING, INC. ARE PER APPLIC~LE
ASTM STANDARDS: C138, C143, C172, C231. CYLINI~S MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM
SOl CH E I~1 AN ESTING, INC.
3~¢hes M. Perdue
General Manager
2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax