Loading...
Lam Lee Add-LR000803 CONCRETE INSPECTION AND COMPRESSION TEST REPORT Client: Alice Lee c/oRealty Capital Corp. Work Order Number: 00-2359 Project: 00-014 Lam Lee Report Number: 00.014.244 SPECIFICATIONS ' - P~0~JE~T DATA Strength (psi): i3000 IDate of Placement: ~8/3/00 iSlump(in.): 14 - 6 ISampled by: Contractor Made ':Air Content(%): ina iWeather. Warm/Humid iConcrete Temp(F): !Not to exceed 100 Supplier/Mix: iPioneer FIELD DATA SET # 1 ticket #: ~Time Batched: i .... ~T~-r~e-~-am~ledi ---i ~Air Content: ~ iUnit Weight (pc0: !Slump (in.): ! !Concrete Temp(F): ~ !Air Temp (F): I iYardage: iLocation/Remarks: iTum lanes brick pockets at south approach - cylinders made by contractor, no other information given SET CYLINDER DATE ~ AGE MAX LOAD ISTRENGTH TEST CYLINDER NOTES NO. NO. :TESTED ~, (days) (lbs) (psi) RESULT SOURCE 1 . I [8/10/00 7 96000 3400 1 2 8/31/001 28 120000 4240 I 3 !8/31/00i 28 129000 4560 NORMAL CYLINDER SIZE: 5X12, AREA:28.27sq. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY WI'FH PROJECT SPECIFICATIONS UNLESS INDICATED "NON-COMPLLa, NCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING. INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231. CYLINDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM ..... eneral Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax