Loading...
Lam Lee Add-LR000801 CONCRETE INSPECTION AND COMPRESSION TEST REPORT Client: Alice Lee c/oRealty Capital Corp. Work Order Number: 00-2324 Project: 00-014 Lam Lee Report Number: 00.014.243 SPECIFICATIONS PROJECT DATA Strength (psi): 4000 iDate (~f~p~Cen~nti - Slump(in.): i4 - 6 iSampled by: LB Air Content(%): na iWeather: Wan'n/humid 'Concrete Temp(F): ~Not to exceed 100 iSuppher/Mix: Pioneer- 9351 FIELD DATA SET # 1 iTicket #: 675359 iTime Batched: 8:50:00 AM Time Sampled: 9:15:00 AM Slump (in.): 4 iAir Content: [ na iUnit Weight (pcf): na iConcrete Temp(F): 80 Air Temp (F): iYardage: 30 Location/Remarks: iSouth turn lane ~. sou~h Lam Lee entrance, 10' south of no, th end SET CYLINDER~ DATE AGE MAX LOAD STRENGTH: TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT SOURCE i I 8/8/00 7 115000 4070 I 2 8/29/00 28 132000 4670 1 3 8/29/001 28 135000 4775 I 4 Discard FIELD DATA SET #2 Ticket #: 675365 Time Batched: I 9:41:00 AM :Time Sampled: 10:05:00 AM na Slump (in.): 4 :Air Content: ~ na iUnit Weight (pcf): 100 Concrete Temp(F): 78 Air Temp (F): 100 Yardage: Location/Remarks: South turn lane on Royalk at south Lam Lee entrance, 100' north of south end SET CYLINDER DATE AGE MAX LOAD iSTRENGTHi TEST CYLINDER NOTES NO. NO. TESTED I (days) (lbs) (psi) i RESULT SOURCE 2 1 8/8/00 7 95000 3360 2 2 8/29/00 28 119500 4230 2 3 $i29/00 25 11S500 4190 2 4 Discard NORMAL CYLINDER SIZE: SX12. AREA:28.27sq. in. UNLESS NOTED HERE: TYPE "A'° CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY W1TH PROJECT SPECIFICATIONS UNLESS INDICATED "NON. COMPLIANCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231. C,~LINDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM S. TECH -NGINEI IG/ TESTING, INC. ///' ~ ,.,,~ ,- ~, ,~...,..: ~-~? ~ ~%~Jame~M. Perdue General Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax