Loading...
Lam Lee Add-LR000706 CONCRETE INSPECTION AND COMPRESSION TEST REPORT Client Alice Lee c/oRealty Capital Corporation Work Order Number: 00-2137 Project 00-014 Lam Lee Report Numbe 00-014.231 SPECIFICATIONS i PROJECT DATA Strength (psi): !4000 iDate of Placement: 7/6/00 Slump(in.): ~4 - 6 ' Not to rSampled by: !LB iAir Content(%): na Weather. ISxunnylHumid Concrete Temp(F): exceed 100 ISupplier/Mix: Pioneer - 9349 FIELD DATA SET # 1 Air Content: !Ticket #: ! 509733 Time Batched: L 7:02:00 AM ITime Sampled: 8:02:00 AM iSlump (in.): 5 314 [ na IUniti Weight (pcf): ! na Concrete Temp(F): I 78 !Air Temp (F): I 88 !Yardage: 20 Location/Remarks: Floor slab leaveout southeast comer SET CYLINDER DATE I AGE MAX LOAD STRENGTHi TEST CYLINDER NOTES NO. NO. TESTED (days) (lbs) (psi) RESULT SOURCE ' I ' 1 7/13/00i 7 75000 2650 1 2 8/3/00 28 1 3 1813100' 28 I 1 4 ! I Hold i NORMAL CYLINDER SIZE: 5X12, AREk28.27sq. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY WiTH PROJECT SPECIFICATIONS UNLESS iNDICATED "NON-COMPLIANCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172. C231. CYt. INDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM SOILTECH ENGINEERING AND TESTING, INC. '~neral Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589,7279 metro · 817.595.0708 fax