Loading...
MacPlaza Phase 2-CS 970130 DEVELOPMENT REVIEW COMMI EE ENGINEERING COMMENTS ITEM: MacArthur ~ Phase 2. PrelOnOmry P~t. to agow the developtnent of a $0,000 square foot reta~ buihfing on a 4.08 acre site, located on the west side of MacAtthur Blvd., approximate~ 186.53' north of the DART ndl r.o.w., at the request of Texas CED ConsOm~on Parmers, lid. DRC DATE: January 30, 1997 and February 6, 1997 CONTACT: SC~e Martin, E.I.T., Assistant CRy Engineer ($04-$679) · I I I ~ · · COMMENT STATUS: ~PRELIMINARY FINAL REVISED AFTER P&Z 1 Preliminary Plat: 1. Need to provide for a 20' sanitary sewer easement across future lot 1.42 acres. The location of sewer line across the adjacent lot should be located such that when the lot develops it does not have pavement on top of it. 2. Lot numbers should be shown on the plat. 3. Provide the franchise utility block on the plat. 4. Provide the metes and bounds for the fire lanes. 5. Impact fees are required. Utility Plan: 6. Try to tie the sewer line into the existing sanitary sewer manhole. 7. Water meter taps cannot be located on the private fire line. 8. The proposed irrigation meter needs to be tapped off existing 8" water. Provide a vault and an easement. Drainage Plan: 9. Need more information before we can allow ADS pipe instead of RCP. The use of ADS storm drainage pipe could be allowed on private property only if a letter is provided requesting a variance. All public storm sewer must be RCP. Site Plan: 10. Provide a 5' sidewalk and brick paver bands at all ingress/egress off MacArthur Blvd. 11. Stripe and sign deceleration lanes. Increase transition to 100' minimum off of abandoned Riverchase Drive. 12. Provide 30' radii at all driveways. Landscape Plan: 13. Brick paver bands are required at all driveways off of MacArthur Blvd.