Loading...
Lakeside V2-LR 960522 REPORT OF CONCRETE COMPRESSIVE STRENGTH CUENT: THE KgOGgR CO Attn: Jeff Kruegar 100 Kroger Drive Keller, TX 76248 PROJECT NO.: 0903506037 REPORT NO.: 40478 PROJEC'F: Kroger 04/~8 DATE OF SERVICE: 4/24/96 Coppell, TX AUTHORIZATION: John REPORT DATE: 5/22/96 SERVICES-' Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CONTRACTOR: David Christopher, Inc. CIA,SS OF CONCRETE: Mix Number 8273 CONCRETE SUPPUER: TXI DATE OF PLACEMENT: 4/24/96 PLANT: 43 TIME SAMPLED: 08: 30AM BY: Anthony Lively SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 68 CONCRETE: 78 STRENGTH: 4000pst @ 28 DAYS TRUCK NO: 458 TICKET NO: 576075 SLUMP: 5" Max. AIR CONTENT(%): 5.75 AIR: N/A LOCATION OF PLACEMENT: METHOD OF TEST: ASTM C-39 Pour ~/5 south parking in line with center of ASTM C-143 building 20 yards from south end REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYENDER MEASURED MAXIMUM CCMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches} TESTED (days) (in.} (sa.in.} (lbs. force} (os~ REMARKS 1 1 5. O0 5/01/96 7 6.00 28.27 84240 2980 1 2 5.00 5/22/96 28 6.00 28.27 116640 4120 1 3 5.00 5/22/96 28 6.00 28.27 1140a0 4030 1 4 HOLD HOLD Technician: Ancho_ny Lively Started: 06:30~ Stopped: ll:30AM Technic lan Report Of Tests Continued On Page 2 ;001 LW Our letters and reDorts ars for the exclusive use Of ~J'te cJlent '.o Wthom they are ac~dresae(~ anq sl~ml not t)e reDroduced except :n ,~U 'M~out the. approval of the testing E1Doratory: The use of ourname must receive out wrfften aooro~aJ. Our lettel's and reootts aDl~y omy tO me sample tested ann/or !flsoecte~, anti are n~t inoicatlve Of the quartiles of a~oarermy ,aemtcal or similar proaucts. 'I'HF. KI~.OGF..~ CO REPORT NO. 40478 I=ROJECl' NO. 0903506037 PAGE 2 DATE OF SERVICE: 4/24/96 SET NO. 2 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: ~fx Number 8273 CONCRETE ~JPPUER: TXI DATE OF PLACEMENT: 4/24/96 PLANT: 43 TIME SAMPLED: 10: OOAM BY: Anthony Lively SPECIFICATION REQUIREMENTS TEMPERATURE ('F) -AIR: 78 CONCRETE: 80 STRENGTH: 4000pst @ 28 DAYS TRUCK NO: 472 TICKET NO: 576296 SLUMP:. 5" Max. AIR CONTENT(%): 5.50 AIR: N/A LOCATION OF PLACEMENT: METHOO OF TEST: ASTM C-39 Pour ~5 paving tn south parking lot in line ASTM C-143 with center of building REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 8 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches) TESTED (days) (in.) Cs~.in.) ~s. force} (os~ REMARKS 2 I 5.75 5/01/96 7 6. O0 28.27 84120 2970 2 2 5.75 5/22/96 28 6.00 28.27 115930 4100 2 3 5.75 5/22/96 28 6.00 28.27 110900 3920 Ave: 4010 2 4 HOI/) Average co~ressive strength of ~o 28 clay cylinders co~lies with specified strength. Technician: An~:ho.ny Lively SCar~:ed: 06:30AM Stopped: ll:30AM Technician Report Distribution: MAXIM/~ TECH..SO~STERN LABS (1) THE I~ROGER CO (1) David Christol:her, inc. (1) City of CoR~[L - Eng. Dept. ¢1) City of P;o.lecl: Manage~ 1001 LW ~ I .e~.~ers...a(td rsoorts are f.~or ~ excl.uslve use of_the client .to vd~om they are addressed am:l shall not be relwoduced exce~ In ~u, .w~mqu~ m~.. alAorova~, of me resting .~oorato~y.. ~r~. use ~ ~me mF~.t~ receive...o~r .written SOpro~L Ou~ lett~s and reports SOl:ay o~y to me semp~e tested encFOr ~nspecte~, an~ are not ~macauve o~ me quenuues o~ NAoar~it]y Ider41cad or ~mllar products.