Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Lakeside V2-LR 960516
REPORT OF CONCRETE COMPRESSIVE STRENGTH CUENT: THE IQ~GER CO Attn: Jeff Kruegar 100 ~Croger Drive Keller, TX 76248 PROJECT NO.: 0903506037 REPORT NO.: 40252 PROJECT: Kroger ~4~8 DATE OF SERVICE: 4/18/96 Coppell, TX AUTHORIZATION: John REPORT DATE: 5/16/96 SERUICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CO~OR~ S~J~ TXI DATE OF PLAINT: 4/18/96 PrAtT: 41 ~M6 $AMP~D: 08: 15AM BY: Steven Holt SPECAFICAllON REQUkREMENTS TEMPERATURE ('F~ - NR: 70 CONCRETF~ 74 STRENGTH: 3500psi @ 28 DAYS TRUCK NO: 459 11CKET NO: 573346 SLUMP. 5" max. MR CONTENT¢~4:4.6 MR: N/A LOCAllON OF PLACEMENT: METHODOFTEST: ASTM C-39 Paving, third strip from west, southwest ASTM C- 143 portion REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 8 X 12 CYUNDERS CYUNDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DLNdETER AREA LOAD STRENGTH SET NQ. (lnches~ TESTED (days) (In.) (s(~in.) ~lb$. force) [osi~ REMARKS 1 1 7. O0 4/25/96 7 6. O0 28.27 91320 3230 1 2 7.00 5/16/96 28 6.00 28.27 127080 4490 1 3 7.00 5/16/96 28 6.00 28.27 121710 6300 1 4 HOLD HOLD Technician: Steven Holt Started: 06:00AM Stopped: 12:30PM Technician Report Of Tests Continued On Page 2 ~ K~:X~~' CO REPORT NO. 40252 ~OJECT N~: 0903506037 PAGE 2 DATE C~ S~WCE: 4/18/96 SeT NO. 2 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CONTRACTOR: David ~hristopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPUER: TXI DATE OF PLACEMENT: 4/18/96 PLANT: 41 33ME SAMPLED: 11: 30AM BY: Steven Holt SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - NR: 74 CONCRETE: 80 S'rRENGTH: 3500pst @ 28 DAYS TRUCK NO: 468 ~qCKET NO: 573653 SLUMP:. 5" ma~. AIR CONTENT(~): 4.8 AIR: ~/A LOCATION OF PLACEMENT: ~-n-loo OF TEST: AS~ C-39 ~av~.ai;, thi=& st:lp £:oa ~est @ no=:heast AS~ C- 143 cor~e= REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYUNDERS CYUNDER MEASURED MAXIMUM COMPRESSIVE MARKED ~I.,~MP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inche~) TESTED (days) (in.) (sa.in.) (lbs. force) ¢osR REMARKS 2 1 4.75 4/25/96 7 6.00 28.27 85340 3020 2 2 4.75 5/16/96 28 6.00 28.27 126490 4470 2 3 4.75 5/16/96 28 6.00 28.27 125230 4430 2 4 HOLD HOLD Technician: SCeven Hole Star:ed: O6:OOAM Stopped: 12:30PM Technician Report Distribution: MAXIM TECH.eSOUTHWESTERN LABS (1) THE rJK)GER CO CI) City ef C(qaell - Eng. De;)t. ~C,~'£ (1) city of c(qae~l - ILcle. ln~. Acthur J~ ~toj ecC