Lakeside V2-LR 960508*- Maxim Tech. e Southwestem Lab. 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 T E C H N O L O G I E S I N C Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CUENT: THE KP. OCF./~. CO Attn: Jeff Kruegar 100 Kroger Drive Keller, TX 76248 PROJECT NO.: 0903506037 RMPORT NO.: 40667 PROJECT: Kroger ~448 DATE OF SERVICE: ~/29/96 Coppell, TX AUTHORIZA'rlON: John REPORT DATE: 5/08/96 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPUER: TXI DATE OF PLACEMENT: 4/29/96 PLANT: 41 ]1ME SAMPtED: 10: OOAM BY: Anthony Lively SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 60 CONCRETE: 72 STRENGTH: 4000psi @ 28 DAYS TRUCK NO: 466 11CKET NO: 579215 SLUMP:. 4.5" AIR CONTENT~): ~.75 AIR: N/A LOCATION OF PLACEMENT: METHOD OF TEST: ASTM C-39 Pour (/7 paving in front of loading dock ASTM C- 143 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 8 X 12 CYUNDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inchesl TESTED (davsl (in,) (sa. in.) ~lbs, force) (~s~ REMARKS I I 5.00 5/06/96 7 6.00 28.27 99340 3510 1 2 5/27/96 28 1 3 5/27/96 28 1 4 HOLD HOLD Technician: Antho.ny Lively Started: 06:30AM Stopped: ll:30AM Technic ian Report Of Tests Continued On Page 2 lOOl LW ~r I ,e~t.~efs. ~ reports .are. f**~ ~ .excl.u$1ve u. ee of_the cJleflt .to whom they .are addressed ~ shall not be reproduced except In ~ .wm~qut.me. approve, o~ m.e 3esu.n,g .~oratpry,. ~np use oy .ou..rnam. e m¥~ receive, our .~p-;t~en a;~o.~. Oui' letters.and reports app~ omy to ~e sample testeo an~m' i~ea. ~ ~ ~ ~ ~ ~ ~ ~et~y identical or smmllar products. THE KROGF.~ CO REPORT NO. 40667 PROJECT NO. 0903506037 PAC~ 2 DATE OF SF_RVIOE: 4/29/96 SET NO. 2 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont 1hued) PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 4/29/96 PLANT: 41 TIME SAMPLED: iO:40AM BY: Anthony Lively SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 78 CONCRETE: 60 STRENGTH: 4000psi @ 28 DAYS TRUCK NO: 387 TICKET NO: 579272 SLUMP:. 4.5" AIR CONTENT(cA): 5.0 AIR: N/A LOCATION OF PLACEMENT: METHOD OF TEST: AST~ C-39 Pour ~7 north end of loading dock ASTM C- 143 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYUNDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAME'FER AREA LOAD STRENGTH SET NO. finches} TESTED (days) (in.) (scl. in.~ fibs. force) (DsO REMARKS 2 1 5.25 5/06/96 7 6. O0 28.27 99980 3540 2 2 5/27/96 28 2 3 5/27/96 28 2 4 HOLI) HOI.D Technician: Anthony LLvely Started: 06:30AM Stopped: ll:30AM Technic Report Distribution: ¢1) THE K~OGER CO MAXIM TECH.~6OUTHI~ESTERN LABS Cl) Oav,d Christopher, [nc. (1) ;i~y of Ccq~peLL - Eng. Dept. (1) ;ity of C~peLL - BLdg. Zmp. ~ Et~r~7 TTI, C;'r ~'" Project Manager 1001 LW ~ le!-t~ers' ~ reports We. fpr .~e 9xclp. slve u. se of._~e cliem .to whom they We addressed .ep._d shall not be rep.':oduced except In _m~_h~.wn~__o~._me~_eppr_ov~_, ~ ~e3esa~l~..m~ora~_c~/; i n~e use m..ouL~a..m.e m.u~., recetve._.cxx .wT~en epp.ro.~L. .Ow. I.ettef. s and reports ~ cm~y co me samima [estec~ an~/or tnspec~e~, en~ are no~ in~cauve cfi me quantme$ or epparefmy i(]ell~cal or similar products.