Lakeside V2-LR 960430 Maxim Tech.. Southwe.tern Lab.
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
T E C H N O L O G I ! $ I N C Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CMENT: THE KROGER C0
Attn: Jeff Kruegar
100 Kroger Drive
Keller, TX 76248 PROJECT NO.: 0903506037
REPORT NO.: 39604
PROJECT: Kroger ~/448 DATE OF SERVICE: 4/02/96
Coppell, TX AUTHORIZA~ON:
REPORT DATE: 4/30/96
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
PROJECT DATA
CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 46 (5 Sack Mix)
CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 4/02/96
PLANT: 41 ~ME SAMPLED: 07: 10AM BY: Anthony Lively
SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 59 CONCRETE: 64
STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 463 ~CKET NO: 563382
SLUMP: 5" Max. AIR CONTENT(%): N/A
AIR: N/A LOCA~ON OF PLACEMENT:
METHOD OF TEST: ASTM C-39 Slab ~/5 Cridline 16 to 21L & 16 to 21E
ASTM C-143
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
CYLINDER MEASURED MAXIMUM COMPRESSNE
MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH
SET NO. (inches) TESTED (days) (in.) (s~.in.) (lbs. force) (psi) REMARKS
1 1 5.25 4/09/96 7 6.00 28.27 90440 3200
1 2 5.25 4/09/96 7 6.00 28.27 94880 3360
1 3 5.25 4/30/96 28 6.00 28.27 126960 4490
1 4 5.25 4/30/96 28 6. O0 28.27 120280 4250
ADDrTIONAL COMMENTS:
Technician time recorded on report number 39554
Technician: Anthony Lively
Technic lan
Report Distribution:
(1) THE KROGER CO MAX~STERN 7S
(1) David Christopher, [nc.
(1) City of Coppe[[ - Eng. Dept.
(1) City of CoppeL[ - Bldg. ]nsp. ~rthur-Etherly III, CET
Proj eot Manager
1001 L~At Our le~ers and reports are for the exclusive use of_the client .to whom they are aadressed and shall not be reproduced except In
full .wttnqut the approval of the testing laboratory, ine use or ourname must receive our w~ttten a~l=rovmL Our letters and reoorts
aopty omy to the sample tested and/or inspecteU, ann are not indicative of the quantAies of ap~arer~y ioenflcaJ or similar products.