Loading...
ST0004-LR010824 ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 ---- ~ Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-047 Report Date: 08/24/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 08/16/2001 Slump 5 in max Sampled By 7uhair Shubbar Air Content 3 % min 6 % max Weather Cloudy Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 816714 Time Batched: n/a Time Sampled: 1:42 pm Slump: 4 in Air Content: 3.6 % Unit Weight: n/a Concrete Temperature: 94° F Ambient Temperature: 93° F Yardage (c.y.): 38 of 60 Placement Location: Paving Sample Location: Repair no's. 16 & 17, West side of North Freeport Pkwy. Cylinder Age Max Load Area Strength Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi'} Type 1 08160101 08/23/2001 7 132940 28.27 4700 unbonded cap 1 08160102 08/23/2001 7 134110 28.27 4740 unbonded cap 1 08160103 08/30/2001 14 1 08160104 08/30/2001 14 1 08160105 09/13/2001 28 1 08160106 09/13/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. M. PE'FTIT · TERRA-MAR, INC. The results presented in this repod pertain only to the specific items tested, This report was produced for the exclusive use of the clJent. Any reproduction of this report, or any pad therein, is strictly prohibited without the express written consent of TMI. Page I of 1