Lakeside V2-LR 960412 (2) Maxim Tech. · Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dall~s, Texas 75222
T E C H N O L O O I E S I N C Telephone: ;14) 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CUENT: THE KROGER CO
ArCh: Jeff Kruegar
100 Kroger Drive
Keller, TX 76248 PROJECT NO.: 0903506037
REPORT NO.: 38903
PROJECT: Kroger (/448 DATE OF SERVICE: 3/15/96
AUTHORIZATION:
Coppell Tx. REPORT DATE: 4/12/96
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
PROJECT DATA
CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 46 (5 Sack)
CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 3/15/96
PLANT: 41 TIME SAMPLED: 07: 43AM BY: Roosevelt Webber
SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 51 CONCRETE: 63
STRENGTH: Not Provided TRUCK NO: 388 TICKET NO: 554914
SLUMP: 3- 5" AIR CONTENT(%): N/A
AIR: N/A LOCATION OF PLACEMENT:
METHOD OF TEST: ASTM C-39 Fourth base from west side, 20 feet from south
ASTM C-143 corner
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 8 X 12 CYLINDERS
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH
SET NO. (inches} TESTED (days} {in.} (sa.in.} ~lbs. force} (~s~3 REMARKS
1 1 5.00 3/22/96 7 6.00 28.27 97400 3440
1 2 5.00 3/22/96 7 6.00 28.27 101490 3590
1 3 5.00 4/12/96 28 6.00 28.27 130270 4610
1 4 5.00 4/12/96 28 6.00 28.27 132610 4690
Technician: Roosevelt Webber Started: 06:30AM Stopped: 09:00AM
Technician
Report Distribution:
(1) THE KROGER CO - MAXIM TECH.~SOUTHWESTERN LABS
(1) David Christopher, inc. /~__ _~ I _.~
(1) City of Coppe[[ - Eng. Dept.
(1) City of Coppe[[ - Bldg. lnsp.
ur ~nerly III, CET
Project Manager
1001 LW Our letters and reports are for the exclusive use ofthe client .to whom they are addressed and shall not be reproduced except In
full without the approval of the testlnc3 aboratory i ne use OT ourname must rece ve our wr~en approval. Our letters and reports
apply only to the sample tested and/Or inspecte~l, and are not indicative of the quantities of apl~areritly identical or simila~ products.