Latter-day-LR 950531Rone Engineers
Geotechnical Consultants
Materials Testing
Concrete Cylinder Test Report
Project
CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS
Number I Date of Observation
D4251B-073 I MAY 01, 1995
To
JOHN R. HORTON, ARCHITECT
trchase Order
leport Date
05~31/95
Location
PIERS #J
Contractor ,..
W. B. KIBLER CONSTRUCTION
Supplier Plant I Truck T~cket
TXI 31 362 3[72107
/
Mix Number Mix Description
8273
Weather Conditions CLOUDY
Time Sampled I Water Added
9:53 AM ] 0.0 GALS
Physical Data
Ambient Temperature (°F) C
66
Dncrete Temperature (°F)
'6
ACTUAL SPE( IFICATIONS
SLUMP (in.) -- 4 1/2
Concrete Cylinder Test(s)
ACTUAL SPE(:IFICATIONS
Specimen Age I Test DateI Tot Load Compressive
No. (Days) (lbs.) Strength (psi)
46A 7 5/08/95 91500 3240
46B 28 5/29/95 120500 4260
46C 28 5/29/95 120000 4240
46D HOLD HOLD
4OOO
Stren
~th Required (psi)
Curing Method I Test Method
ASTM C 31I ASTM C 39
Remarks and/or Distribution
Standard 6" x 12" Engineer/Technician
Area 28.27 sq. in.
Distribution: (1) --JOHN R. HORTON
(1) -- W.B. KIBLER CO~NSTRUCTION
(1) -- BILL FOWKES
(1) -- CITY OF COPPELL
LIMITATIONS: The test results presented herein were prepared based upon the el~cific samples provide~ for tsstir~h We assume n
quality (composition, appears'ice, perform~ce, etc.} or any ot~r feature of limilE subject matter provid~ by perso~ or co~i~iom
Our letters ~ reports a¢e for t~ exclusive ~e o~ t~ clients to whom t~y are ~dreesed.
c:\wpwin\forms\cylinder.rpt-95/kjh
KEVII~ TUCKER
responsibility for verietion in
over which we have no control.
May 31, 1995