Loading...
Lakeside V2-LR 960403MAXIM TECHNOLOGIES, INC. P.O. Box 224227 * 2575 Lone Star D~b'® * Dala., Texa~ 75212 ° 214/631 - 2700 Melro 2~3-1133 REPORT NO: 39620 CLIENT: The Kroger Company DATE: April 3, 1996 ' PROJECT: Kroger Store #448, Coppell, Texas CEENT NO: 0903506037 PAGE I of 2 A FLOOR SURFACE ANALYSIS LOCATION SURVEYED : Slab on Grade, E.5to J.5 and 17 to 21 Placement 5 APPROXIMATE AREA : 6,181 sf ASTM STANDARD : ASTM E 1155 INSTRUMENT USED : "Dipstick", manufactured by Face Technologies; Norfolk, Virginia SAMPUNG METHOD : Point elevations were measured at regular 12 inch intervals along straight lines up to 29 feet in length. The elevation differences between all adjacent reading points, the arithmetic differences between all adjacent 12 inch elevation differences, and b~e elevation differences between all points separated 10 feet were then calculated. Estimates of the floor's flatness and level- ness F-Numbers (Fl & FI) were obtained through a statistical analysis of these calculated profile values. The tabular data is available upon request. COMBINED OVERALL VALUE RESULTS: PLACEMENT 5 90% Cont. Range 90% Conf. Range Ff - + FI - + 31.8 2g.4 34.3 21.7 m., 23.8 ' Based upoo the numbe~ of samples taken, the~® is & 90% certainty thai the actual F-Numbers of the surlaces surveyacl WILL fall within the ranges which follow Ne respective es~mated Flalne~l~ and Levelness F--Numbers. spECIFIED'U'Mi'rS'?~'i ' :..:!i.:":~.--..-'.:.'.:: ~ .... '.: ' ' i '.i ..: - ::.' . '. ~ ~'..:'." . .?':'. '::..~:::i-:~-:.Spe6ified.~&ali!Vai~eii.Ff:2~.::-.: ;: :: ..: . .-....:.....:... :.: .. . .--::..:: . i::..':~:;.!'i':":' :$iS&Cifi~.-O~er~li'V~lL~:'i:i~i~:: 'ii:::~'~:':i.-."-:;.' .-:::. :--:~i-i:~.:. ~.'?;;::i..-:??'i:i:. ========================================= : C. OMMENTS: The Composite F-Flatness and F-Levelness Numbers on this placement are 'SUPERIOR'." to the specified limits. TECHNICIAN: L. BRACKEN Maxim Tecfixsologies, Inc. ARTHUR ETHERLY III, CET Construction Materials Engineering Division MAXIM TECHNOLOGIES INC. REPORT NO: 39620 CLIENT: The Kroger Company DATE: April 3, 1996 PROJECT: Kroger Store #448, Coppell, Texas CLIENT NO: 0903506037 PAGE 2 of 2 A FLOOR SURFACE ANALYSIS LOCATION SURVEYED : Slab on Grade, E.5 to J.5 and 17 to 21 Placement 5 APPROXIMATE AREA : 6,181 s.f. PLACEMENT DATE 04102/96 90% Conf. Range 90% Conf. Range Survey Line Pts. Ff - + FI - + 1- I 29 25.40 19.41 31.39 41.96 32.07 51.85 I - 2 29 28.21 21.56 34.86 16.27 12.43 20.11 1- 3 29 22.91 17.51 28.31 13.10 10.01 16.19 1 - 4 29 30.27 23.13 37.41 32.34 24.71 39.97 I - 5 29 64.21 49.07 79.35 21.58 16.49 26.67 1 - 6 29 49.17 37.58 60.76 52.56 40.17 64.95 I - 7 29 52.11 39.82 64.40 31.97 24.43 39.51 I - 8 29 30.97 23.67 38.27 20.27 15.49 25.05 OVERALL AREA Pts. Ff - + FI - + COMBINED: 232 31.8 29.40 34.30 21.7 19.60 23.80 ° Based upon the number o~ samples taken, them is a g0% certainty that the actuaJ F-Numbers o1' the surfaces surveyed WILL fall within the range~ which follow the m~e ,~tJmated Flatne~ and Levelness F-Numbem. ' .'~.-:: :':":. ~:'.'i~latiiei~'~!"F~NU~ber:i ":.~::' ."" Specifi6d Ov~rall:'Value':'!(S~.::FF:':25" '.b. Eevelness;F~Numb'er:--.-:::: ;SPeCified Overali-Value"(SOV)'"-'FL:20-..":'-~':'i::