Lakeside V2-LR 960327 (2), Maxim Tech.. Southwestern Labs 2575 Lone S~r Dr. · P.O. Box 224227 Dallas, Texas 75222 i' 1= ¢ H N O L O G I E S I N ¢ Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: TEE KROGER CO Attn: Jeff Kruegar 100 Kroger Drive Keller, TX 76248 PROJECT NO.: 0903506037 REPORT NO.: 38162 PROJECT: Kroger ~448 DATE OF SERVICE: 2/28/96 AUTHORIZATION: Coppell Tx. REPORT DATE: 3/27/96 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 2/28/96 PLANT: 41 TIME SAMPLED: 08: 20AM BY: SCeven Holt SPECIFICATICN REQUIREMENTS TEMPERATURE ('F) -AIR: 38 CONCRETE: 62 STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 472 TICKET NO: 545416 SLUMP: 4- 6" AIR CONTENT(%): 6.5 METHOD OF TEST: ASTM C-39 LOCATION OF PLACEMENT: ASTM C-143 Fire lane north of building, east portion REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMI IM COMPRESSIVE MARKED SLUMP DATE ' AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches) TESTED {days) (in.) (sQ.in.) (lbs. force) IDsi) REMARKS 1 1 6.50 3/06/96 7 6.00 28.27 97160 3440 1 2 6.50 3/27/96 28 6.00 28.27 126260 4470 1 3 6.50 3/27/96 28 6.00 28.27 134910 4770 1 4 HOLD HOLD Technician: Steven Holt Started: 06:00AM Stopped: ll:30AM Technician Report Of Tests Continued On Page 2 ~.C01 LW Ot;r letters and rel3orts are for the exclusive use of the client to whom they are addressed and shall not be reproduced exce;3t in fall without the apprcval of the testln(3 laooratory The use of ourname must receve our wr tten approva. Our etters and retorts apply only to the sample tested and/~r inspectei:l, an(~ are not ,nd~catlve of the quantities of apparently :(~entical or similar pro(3ucts. THE KROGER CO REPORT NO. 38162 FROJECT NO. 0903506037 PAGE 2 DATE OF SERVICE: 2/28/96 SET NO. 2 REPORT OF CONCRETE COMPRESSIVE STRENGTH ( Cont i nued) PROJECT DATA CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 2/28/96 PLANT: 41 TIME SAMPLED: 10: 05AM BY: Steven Holt SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 38 CONCRETE: 60 STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 381 TICKET NO: 545586 SLUMP: 4-6" AIR CONTENT(%): 6.2 METHOD OF TEST: ASTM C-39 LOCATION OF PLACEMENT: ASTM C-143 Fire lane north of building, west portion REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches~ TESTED (days) (in.i (sci.in.) (lbs. force) (psi) REMARKS 2 1 5.50 3/06/96 7 6.00 28.27 94280 3330 2 2 5.50 3/27/96 28 6.00 28.27 119250 4220 2 3 5.50 3/27/96 28 6.00 28.27 130060 4600 2 4 HOLD HOLD Technician: Steven Holt Started: 06:00AM Stopped: ll'30AM Technician Report Distribution: M~STERN LABS (1) THE KROGER CO (1) David Christopher, inc. (1) City of Copper[ - Eng. Dept. _ -~ (1) City of Coppell - Bldg. Insp. Arthur Etherly III, CET Proj ecl Manager ~001 LW Our letters and report, s are for the exclusive use cf t,he c~ient to whom they are addressecl and shall not be reproduced exceot In ~ w~,out the aDcrova of *.he test ng laboratory The use of ourname must receive our written approval. Our letters and reports apply only to the' sample tested &nd/or ,nspected, an3 are not :noicat~ve of :he quamities of apparently identical or similar products.