Lakeside V2-LR 960320 (2) Maxim Tech.. Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas. Texas 75222 T~qephone: (214) 631-2700 T E C H N O L O G I E S I N C FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: THE KROGER CO Attn: Jeff Kruegar 100 Kroger Drive Keller, TX 76248 PROOEOT NO.: 0903506037 REPORT NO.: 38657 PROOMCT: Kroger ~/448 DATE OF SERWGE: 3/11/96 AUTHORIZAqqON: Coppell Tx. REPORT DATE: 3/20/96 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. PROJECT DATA CCNTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Nuaber 8273 CONCRETE SUPPLIER: T~I DATE OF PLACEMENT: 3/11/96 PLANT: 41 TIME SAMPLED: 09:10AM BY: Paul D. Butler SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 45 CONCRETE: 49 STRENGTH: 4000psi @ 28 DAYS TRUCK NO: 452 TICKET NO: 550858 SLUMP: 4" AIR CONTENT(%): 7,8 UNIT WEIGHT(pc'O: N/A AIR: 4-6:{ LOCATION OF PLACEMENT: METHOD OF TEST: ASTM C-39 75' south of the north end pavement; on ASTM C-143 parking east of bldg., east lane, from the ASTM C-138 north side of bldg. to the south side REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches) TESTED (days) (in.) (SCl,in.) (lbs. force) (13si) REMARKS 1 1 4.00 3/18/96 7 6.00 28.27 81860 2890 1 2 4.00 3/18/96 7 6.00 28.27 84310 2980 1 3 4/08/96 28 1 4 4/08/96 28 ADDITIONAL COMMENTS: Note: Contractor notified of high air content Technician: Paul D. Butler Started: 06:00AM Stopped: 01:00PM C.E.T. Report Of Tests C~nt~nued On Page 2 1001 LW Our letters and reports are. for the exclusive use of_the client .to whom they .are ad. dressed ~.n.d shall not .be_reprp~ced ex. copt In. full .wffho. ut the approva. I Pt the.testing laboratory: i n.e use o! pu.r, na.m, e rn.us3 recelvq...,our wt. nten aPprov, a.l._,uu.r le~e.rs.,ano rep. on.s apply only to the sample testea and/or inspecteo, ano are not inolca~lve pT me quarnitles PT apparenay ~oen~lcal or similar proauc~s. THE KROGER CO REPORT NO. 38657 PROJECT NO. 0903506037 PAGE 2 DATE OF SERVICE: 3/11/96 SET NO. 2 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont i nued) PROJECT DATA CONTRACTOR: David Christopher, Inc. crASS OF CONCRETE: Mix Number 8273 CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 3/11/96 PLANT: 41 TIME SAMPLED: ll:00AM BY: Paul D. Butler SPECIFICATION REQUIREMENTS TEMPERATURE ('Fl - AIR: 54 CONCRETE: 51 STRENGTH: 4000psi @ '28 DAYS TRUCK NO: 474 TICKET NO: 551010 SLUMP: 4" AIR CONTENT(%): 6.0 UNIT WEIGHT(pcf): N/A AIR: 4-6% LOCATION OF PLACEMENT: METHOD OFTEST: ASTM C-39 75' North of the south end pavement; on ASTM C-143 parking east of bldg., east lane, from the ASTM C-138 north side Co south side of bldg. REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches) TESTED (days) (in.) (sq.in.) (lbs. force) (13si) REMARKS 2 1 4.50 3/18/96 7 6.00 28.27 76840 2720 2 2 4.50 3/18/96 7 6.00 28.27 80640 2850 2 3 4/08/96 28 2 4 4/08/96 28 Technician: Paul D. Butler Started: 06:00AM Stopped: Oi:OOPM C.E.T. Report Distribution: MAX~WESTERN LABS (1) THE kROGER CO (1) David Christopher, Inc. (1) City of Coppe[[ - Eng. Dept. / ~ ).c~ ~f~//~- ' '~ (1) City of Coppe[[- 8[dg. Insp. ~ ~l~ei~[~-~ T I, CF.T 1001 LW Our letters and reports are for the exclusive use ofthe client.to whom they are ad. dressed a.E~d shall not .be fepr. o.d. uced ex. cept in. ful without the approval of the testing laboratory, ine use oT pu.r. na.m.e must receive put vtr. r~en approya). .c~u.r let~efs..ano rep. oqs apply only to the sample tested and/or mspecte~l, and ~e not incllCatlve of the quantities oT apparent y ~clentmcm or slmlmr proouc~s. ' ......