Loading...
Lakeside V2-LR 960304 Maxim Tach. · Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 T E C H N O L O G I E S I N C FAX: (214} 920-1891 REPORT OF IN-PLACE DENSITY CLIENT: TH~. KRO~ER CO Attn: Jeff Kruegar 100 Kroger Drive Keller, TX 76248 PROJ£CTNO.: 0903506037 REPORT NO.: 37957 PROJECT: Kroger ~448 DATE OF SERVICE: 2/22/96 AUTHORIZATION: John Coppell Tx. REPORT DATE: 3/04/96 SERVICES: Perform in-place density and moisture content tests to determine the degree of field compaction. PROJECT DATA MOISTURE/DENSITY RELATIONS CONTRACTOR: David Christopher, :[nc. OPTIMUM MAXIMUM MATERIALS MOISTURE % DENSITY I~cf TESTOF: Utility Backfill & 36653 Red clay sand 13.0 117.5 paving subgrade. METHOD OF TEST: DENSITY: ASTM D2922 SPECIFICATION MOISTURE: ASTM D3017 DENSITY: 95% Dry Density MOISTURE: -+ 2% REPORT OF TESTS FIELD OPTIMUM FIELD MAXIMUM TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY NO LOCATION (%) (%) (Pcf) (Pcf) (% max) 1. 4" Plumbing line at H.5/6.0 line, final grade. 11.2 13.0 112.6 117.5 96 2. 4" plumbing line at H.5/5.0 line, final grade. 11.0 13.0 112.0 117.5 95 3. Paving subgrade 75' E., 10' $. of N.E. corner building. 12.0 13.0 113.4 117.5 97 4. Paving subgrade, 75' E. 20' N. of S.E. corner building. 11.7 13.0 113.1 117.5 96 Report Of Tests Continued On Page 2 1007 JS Ou~ letter~ end report~ ara fo~ the excl,,~ve u~ ol t~ cli~ to wh~ t~y ~e ~r~ ~ ~1 ~t ~ re~ ex~ in f~l w,tho~ apply ~y to t~ a~ple TH1; ~ROG~..R CO REPORT NO. 37957 PROJECT NO. 0903506037 PAGE 2 DATE OF SERVICE: 2/22/96 REPORT OF TESTS ¢Continued) FIELD OPTIMUM FIELD MAXIMUM TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY NO LOCATION (%) (%) (Peri (Pcf) (% max) 5. Paving subgrade 30' N. & 100' E. of N.W. corner building. 11.3 13.0 113.2 117.5 96 6. Paving subgrade 30' N. & 20'E. of N.W. corner building. 11.4 13.0 113.0 117.5 96 7. Paving subgrade 20' W. & 10'S. of N.W. corner building. 11.6 13.0 113.1 117.5 96 8. Paving subgrade 50' W. & 50' S of N.W. corner building. 11.8 13.0 113.0 117.5 96 Test results on this report meet project specifications as noted on page 1. Techoi¢ian: Paul D. Butler Started: 11:30AM Stopped: 01:30PM C.E.T. Report(1)(1) DavidTHEDiStribution:KROGERchristopher,CO Inc. M~H . e~O~rTHWESTERN LABS E , CET 1007 JS O~ I~em ~ rep~ ~e for ~ eFcl~ve ~ of t~ ~t to w~ t~y ~e ~r~ ~ ~1 ~t ~ re~ ~pt in f~l w~t~ ~ ~ovM of ~ t~tl~ ~ltory. T~ ~ of.~ ~ r~:v~ ~ wr~en ~ovd. O~ I~e~ ~ re~ ~ply o~y tO t~ s~ple t~ ~/~ :~, ~ ~e ~t ~iCltlVe of t~ qu~tz~ of ip~ently ~cd ~ ~mil~ pr~u~.