Lakeside V2-LR 960227 Maxim Tech. · Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
T E ¢ H N O L O G I E S I N ¢ Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CEENT: THE KROGER CO
Attn: Jeff Kruegar
100 Kroger Drive
Keller, TX 76248 PROOECT NO.: 0903506037
REPORT NO.: 37693
PROJECT: Kroger ~/448 DATE OF SERVICE: 2/16/96
AUTHORIZATION: John
Coppell Tx. REPORT DATE: 2/27/96
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
PROJECT DATA
CONTRACTOR: David Christopher, Inc. CLASS OF CONCRETE: Mix Number 46
CONCRE'rE SUPPLIER: TXI DATE OF PLACEMENT: 2/16/96
PLANT: 41 TIME SAMPLED: N/A BY: Marlo Villanueva
SPECIFICATION REQUIREMENTS TEMPERATURE ('F) - AIR: 42 CONCRETE: 50
STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 451 'nCKET NO: 538196
SLUMP: 5" Max, AIR CONTENT(%): N/A
AIR: N/A LOCATION OF PLACEMENT:
METHOD OF TEST: ASTM C-39 Sampled @ footings for bolt settings
ASTM C-143 F/27-5 & G/27-5.
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH
SET NO. (inches) TESTED (days) (in.) (sa.in.) (lbs. force) (psi) REMARKS
1 1 4.75 2/23/96 7 6.00 28.27 124650 4410
1 2 4.75 2/23/96 7 6.00 28.27 121160 4280
1 3 3/15/96 28
1 4 3/15/96 28
Technician: Marlo Villanueva Started: ll:30AM Stopped: 01: 30PM
Technic ian
Report Distribution: MAXIM TECH.,S ;)UTHWESTERN LABS
(1) THE KROGER CO
(1) David Christopher, Inc. ~ he~l~%
(1) City of Coppe[[ J
Et , CET
1001 LW Our letters and reports are for the exclusive use of the client to w~om they are addressed and shall not be reproduced exceot In
full without the aDDrOVal of the testing laboratory The use of ourname must receive our wr~ten approval. Our letters and ret)orts
apply only to the sample tested and/or inspecte~], and are not inclicative of the quantities of apparently identical or similar products.