Latter-day-LR 951017Rone Engineers
Geotechnical Consultants
Materials Testing
Concrete Cylinder Test Report
Project
CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS
Number
D4251B-100
IDate of Observation
SEPTEMBER 28, 1995
IPulchase Order
Relort Date
10/17~95
57A 7 10/05/95
57B 28 10/26/95
57C 28 10/26/95
57D HOLD HOLD
Time Sampled
3:00 PM
Physical Data
ACTUAL SPEC IFICATIONS
SLUMP (in.) -- 4
ENTRAINED AIR (%) -- 5.8
Concrete Cylinder Test(s)
ACTUAL SPEC IFICATIONS
Weather Conditions PARTLY CLOUDY
TXI 41 467 I 442936
Mix Description
/
Ambient Temperature (°F) I Co
86 I 9(3
IWater Added
20.0 GALS
Tot Load I Compressive
{lbs.) I Strength {psi)
90000 3180
40OO
Streng
Curing Method I Test Method
ASTM C 31I ASTM C 39
Remarks and/or Distribution
Distribution: (1) --JOHN R. HORTON
(1) - W.B. KIBLER CONSTRUCTION
(1) - BILL FOWKES
(1) - CITY OF COPPELL
UMITATIONS: The t~t r#utt~ preeented h~ein were prepared breed upen. t~...apecifi, c. ~mpl# prov' ,M~I, f~ tearing. We ~ ne
Cludity (~ompoeition, ~ppearm'ce, pmfo~m~flce, etc.) or ~ other feeture or mm,4~ mJOlect mstter ixovmea oy per~on~ o~ cm-m~t~on~
Ou~ lettm and refln ere f~' the exc~uaive uee ef the dien~ to whom they n
c:\wpwin\forms\cytinder.rpt-95/kjh
~crete Temperature (°F)
Required (psi)
re~pamibility for v~i/tion in
wet which we have no corm'd.
RoneEngineers
October 17, 12BIB
Standard 6" x 12' I Engineer/Technician
Area 28.27 sq. in.
I
CHUCK :~AY
Mix Number
8273
To
JOHN R. HORTON, ARCHITECT
Location
PAVING REPAIR AT ENTRANCE, WALL AT N.W. SIDE OF ENTRANCE TO BLDG & PORTION OF W SIDEWALK
Contractor
W. B. KIBLER CONSTRUCTION