Latter-day-LR 951017Rone Engineers Geotechnical Consultants Materials Testing Concrete Cylinder Test Report Project CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS Number D4251B-100 IDate of Observation SEPTEMBER 28, 1995 IPulchase Order Relort Date 10/17~95 57A 7 10/05/95 57B 28 10/26/95 57C 28 10/26/95 57D HOLD HOLD Time Sampled 3:00 PM Physical Data ACTUAL SPEC IFICATIONS SLUMP (in.) -- 4 ENTRAINED AIR (%) -- 5.8 Concrete Cylinder Test(s) ACTUAL SPEC IFICATIONS Weather Conditions PARTLY CLOUDY TXI 41 467 I 442936 Mix Description / Ambient Temperature (°F) I Co 86 I 9(3 IWater Added 20.0 GALS Tot Load I Compressive {lbs.) I Strength {psi) 90000 3180 40OO Streng Curing Method I Test Method ASTM C 31I ASTM C 39 Remarks and/or Distribution Distribution: (1) --JOHN R. HORTON (1) - W.B. KIBLER CONSTRUCTION (1) - BILL FOWKES (1) - CITY OF COPPELL UMITATIONS: The t~t r#utt~ preeented h~ein were prepared breed upen. t~...apecifi, c. ~mpl# prov' ,M~I, f~ tearing. We ~ ne Cludity (~ompoeition, ~ppearm'ce, pmfo~m~flce, etc.) or ~ other feeture or mm,4~ mJOlect mstter ixovmea oy per~on~ o~ cm-m~t~on~ Ou~ lettm and refln ere f~' the exc~uaive uee ef the dien~ to whom they n c:\wpwin\forms\cytinder.rpt-95/kjh ~crete Temperature (°F) Required (psi) re~pamibility for v~i/tion in wet which we have no corm'd. RoneEngineers October 17, 12BIB Standard 6" x 12' I Engineer/Technician Area 28.27 sq. in. I CHUCK :~AY Mix Number 8273 To JOHN R. HORTON, ARCHITECT Location PAVING REPAIR AT ENTRANCE, WALL AT N.W. SIDE OF ENTRANCE TO BLDG & PORTION OF W SIDEWALK Contractor W. B. KIBLER CONSTRUCTION