Loading...
Magnolia Village-CS001207 DEVELOPMENT REVIEW C OMMI i 'I ENGINEERING COMMENTS ITEM: Magnolia Village. Lot 1. Block A, Minor Plat. to allow the development of a 15,600 square foot retail center on approximately 2.1667 acres of property located south of the southwest corner ofS. H. 121 and Denton Tap Road, at the request of the Second Century Investments. DRC DA TE: November 30, 2000 and December 7, 2000 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679) .COMMENT STATI2S: I~'d~$t~$tt.IARY REVISED AFTER P&Z 1. An additional 10' of right-of-way needs to be dedicated adjacent to Denton Tap Road. 2. A deceleration lane needs to be provided for proposed driveway on Denton Tap Road which could require additional right-of-way dedication. 3. The 24" fire lane and utility easement shown on the plat should also be labeled as a mutual access easement. 4. The Floodplain Administrator's signature block needs to be provided on the plat. $. The bearing shown adjacent to Denton Tap Road does not match the legal description of the existing right-of-way on Denton Tap Road. 6. A utility plan needs to be provided to determine if proposed and/or additional easement will be needed. What is proposed in the 10' wide water easement? 7. A 20' wide sanitary sewer easement needs to be provided along the west side of the property. 8. The proposed driveway onto Denton Tap Road needs to align with existing hooded left turn lane on Denton Tap Road.