Loading...
Magnolia Park-LR 980619FUGRO SOUTH, INC. CLIENT: PROJECT: FIELD DENSITY REPORT Eastern Development Magnolia Park, Coppell, Texas Number 1 TEST NO. 568 569 570 571 572 573 574 Remarks; REPO PF MOISTURE/DENSITY RELATIONS Material Proc De. criptlon Maximum Dry Der~it~ Dark gray and medium brown very silty clay 110.3 17 16 18 18 17 17 TEST RESULTS PROCTOR LOCATION UNIT DRY MOIS' NO. WEIGHT CONTENT 1 42 inch RCP, Line B, station 0+50, 5 feet 106.0 19 below grade I 42 inch RCP, Line B, station 1+00, 4 feet 108.7 below grade 1 36 inch RCP, Line B, station 1+50, 3 feet 108.5 below grade: 1 36 inch RCP, Line B, station 2+00, 2 feet 108.0 below grade 1 36 inch RCP, Line B, station 2+50, 1 foot 108.6 below grade I 36 inch RCP, Line B, station 3+00, 6 feet 107.2 below grade 1' 36 inch RCP, Line B, station 3+50, 5 feet 106.4 below grade All densities meet project specifications unless otherwise noted. FUGRO SOUTH, INC, Burl Cooper Fugro South Technician Eastern Development - Preston Skaggs City of Coppeil - Larry Davis Metro-Plex Excavating - Paul Bosco Checked by: C /' SMH/mv Distribution: 80 Vi~go Lane; Dallas, Texa~ 75229 )7'2)484-8301; Fax (972) 620-732~ ~,T DATE: June 19, 1998 :OJECT NO.: 0771-2112 tor Results (pcf) Optimum Moisture (%) 16.0 *URE PERCENT OF ;'ERCENT MAXIMUM DENSITY 2 96.1 .5 98.5 .8 98.4 .0 97.9 98.5 97.2 ,8 96.5 FUGRO SOUTH, INC. FIELD DENSITY REPORT CLIENT: Eastern Development PROJECT: Magnolia Park, Coppell, Texas 2~ REPO PR~ Number 1 TEST NO. 575 576 577 578 579 580 581 Remarks: MOISTURE/DENSITY RELATIONS Material Proc1 De~cripflon M~ximum Dry Density, Tan shaley sandy clay mixed with brown sandy 103.2 clay TEST RESULTS PROCTOR LOCATION UNIT DRY MOISTI NO. WEIGHT CONTENT P 1 36 inch RCP, Line B, station 4+00, 4 feet 101.9 20.~ below grade 1 36 inch RCP, Line B, station 4+25, 3 feet 99.4 below grade 1 36 inch RCP, Line B, station 4+50, 2 feet 99.2 below grade 1 36 inch RCP, Line B, station 5+00, I foot 100.0 below grade 1 30 inch RCP, Line B-l, station 0+50, 5 98.6 feet below grade 1 30 inch RCP, Line B-l, station 0+75,. 4 98.6 feet below grade 1 30 inch RCP, Line B-l, station 1+00, 3 98.7 feet below grade All densities meet project specifications unless otherwise noted. 23.l 22..' 20.! 23.l 21 Bud Cooper Fugm South Technician FUGRO SOUTH, INC. SMH/mv Distribution: Eastern Development - Preston Skaggs City of Coppell - Larry Davis Metro-Plex Excavating - Paul Bosco Checked by:~ 0 virgo Lane; Dallas, Taxa~ 75229 ~/2) 484-8301; Fax (9/2) 820-7328 tT DATE: June 19, 1998 :MECT NO.: 0771-2112 or Requite :pcf) Optimum Moisture (%) 19.5 IRE PERCENT OF ERCENT MAXIMUM DENSITY 98.7 95.5 95.5 95.6