Mansions Phase 1-LR 990113 Flone Engineere, Inc. ' 1 :~'~4 Goodnight Lane ; TeL (972) 241-451''~- RoneEnaineers Dallas;Fort Worth Dallas. Texas Metro (972) 263-I 555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 1 of 4 Report No: 3137-D7429-356 Sample Date: December 29, 1998 Client: Western Rim Services Report Date: January 13, 1999 Location: Building//13 Technician: Leo Ruiz # Tendon Location Jack Force Gauge Required Elongations Elongations To~ Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance I B-29 Start at S.W. 33K 7700 2.125 2.125 YES 2 B-29 Southwest Edge 33K 7700 2.125 2.125 YES 3 S-48 Southwest Edge 33K 7700 3.625 3.75 YES 4 B-30 Southwest Edge 33K 7700 2.125 2.125 YES 5 S-101 Southwest Edge 33K 7700 7.50 7.50 YES 6 B-30 Southwest Edge 33K 770~. 2.125 2.0 YES 7 B-30 Southwest Edge 33K 7700 2.125 2.0 YES 8 B-30 Southwest Edge 33K 7700 2.125 2.0 YES 9 B-57 Southeast Edge 33K 7700 4.375 4.25 YES 10 S-$7 Southeast Edge 33K 7700 4.375 4.50 YES 11 B-78 Southeast Edge 33K 7700 5.125 5.0 YES 12 S-63 Southeast Edge 33K 7700 4.875 4.875 YES 13 S-62 Southeast Edge 33K 7700 4.75 4.50 YES 14 B-62 Southeast Edge 33K 7700 4.75 4.75 YES 15 S-62 Southeast Edge 33K 7700 4.75 4.50 YES 16 S-62 Southeast Edge 33K 7700 4.75 4.875 YES 17 B-65 Southeast Edge 33K 7700 5.0 4.75 YES 18 S-65 Southeast Edge 33K 7700 5.0 4.75 YES 19 S-65 Southeast Edge 33K 7700 5.0 5.0 YES Equipment ID: Ram No: 97-267 Pump No: 03196C Gauge No: 97-267 Equipment Calibration Date: 12/11/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no respomibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-~56-98\ST January 13, 1999 ~k~ ~°n~ ~ng~n~r3' ~nc' 1 ~-'-~'34 G°°dnight Lane : Tel' (972) 24~1-451"~-., RoneEn~~ Daflas. For1 Worth Dallas, Texas i Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-356 Sample Date: December 29, 1998 Client: Western Rim Services Report Date: January 13, 1999 Location: Building//13 Technician: Leo Ruiz # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 20 S-61 Southeast Edge 33K 7700 4.625 4.50 YES 21 S-61 Southeast Edge 33K 7700 4.625 4.625 YES 22 S-64 Southeast Edge 33K 7700 4.75 4.50 YES 23 S-64 Southeast Edge 33K 7700 4.75 4.75 YES 24 S-64 Southeast Edge 33K 7700 4.75 4.50 YES 25 S-62 Souu'u~st Edge 33K 7700 4.625 4.75 YES 26 S-64 Southeast Edge 33K 7700 4.75 4.75 YES 27 B-64 Southeast Edge 33K 7700 4.75 5.0 YES 28 S-62 Southeast Edge 33K 7700 4.625 4.875 YES 29 S-62 Southeast Edge 33K 7700 4.625 4.75 YES 30 B-69 Southeast Edge 33K 7700 5.25 5.125 YES 31 S-69 Southeast Edge 33K 7700 5.25 5.125 YES 32 S-69 Southeast Edge 33K 7700 5.25 5.0 YES 33 S-69 Southeast Edge 33K 7700 5.25 5.25 YES 34 B-69 Southeast Edge 33K 7700 5.25 5.125 YES 35 S-69 Southeast Edge 33K 7700 5.25 5.25 YES 36 S-69 Southeast Edge 33K 7700 5.2.5 5.0 YES 37 S-69 Southeast Edge 33K 7700 5.25 5.0 YES 38 S-61 Southeast Edge 33K 7700 4.625 4.50 YES Equipment ID: Ram No: 97-267 Pump No: 03196C Gauge No: 97-267 Equipment Calibration Date: 12/11/98 Comments: Distribution: i (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were pt~red based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leuers and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports~D7429-~6-98\ST January 13, 1999 none Englneer.~? Inc. ' 14~""""""""'~4 Goodnight Lane Tel. (972) 241-451 ~- RoneEnaineers Dailas, Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-356 Sample Date: December 29, 1998 Client: Western Rim Services Report Date: January 13, 1999 Location: Building//13 Technician: Leo Ruiz # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 B-32 Southeast Edge 33K 7700 2.25 2.125 YES 40 S-32 Southeast Edge 33K 7700 2.25 2.125 YES 41 S-61 North Edge 33K 7700 4.625 4.5 YF_~ 42 B-61 North Edge 33K 7700 4.625 4.5 YES 43 S-70 North Edge 33K 7700 5.375 5.25 YES 44 S-98 Nonfl Edge 33K 7700 7.50 7.125 YES 45 S-I01 North Edge 33K 7700 7.75 7.875 YES 46 B-75 North Edge 33K 7700 5.625 5.875 YES 47 S-101 North Edge 33K 7700 7.75 7.50 YES 48 S-102 North Edge 33K 7700 7.875 7.875 YES 49 S-102 North Edge 33K 7700 7.875 7.875 YES 50 S-102 North Edge 33K 7700 7.875 7.75 YES 51 B-76 North Edge 33K 7700 5.625 5.875 YES 52 S-98 North Edge 33K 7700 7.50 7.50 YES 53 S-98 North Edge 33K 7700 7.50 7.25 YES 54 S-98 North Edge 33K 7700 7.50 7.50 YES 55 S-98 Nor& Edge 33K 7700 7.50 7.50 YES 56 S-101 Nor& Edge 33K 7700 7.75 7.25 YES 57 B-74 Nor& Edge 33K 7700 5.50 5.25 Equipment ID: Ram No: 97-267 Pump No: 03196C Gauge No: 97-267 Equipment Calibration Date: 12/11/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consultitxg LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no consol. Our letters and reports are for the exclusive use of the clients to whom they are ~dressed. c:\wpwin\reports\D7429-~56-98\ST January 13, 1999 .o.. Goo n,ght Lane . (97 ) RoneEnoineers Dallas.-'Foc, WOC, hDallas. Texas Metro (972) 263-'15~5 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-356 Sample Date: December 29, 1998 Client: Western Rim Services Report Date: January 13, 1999 Location: Building//13 Technician: Leo Ruiz # Tendon Location lack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (I) End (2) Elongations Tolerance 58 S-101 North Edge 33K 7700 7.75 7.785 YES 59 S-101 Nor~ Edge 33K 7700 7.75 7.50 YES 60 S-101 North Edge 33K 7700 7.75 7.50 YES 61 B-79 North Edge 33K 7700 6.0 5.75 YES 62 S-15 North Edge 33K 7700 0.875 .785 YES 63 S-27 North Edge 33K 7700 2.0 2.125 YES 64 S-27 North Edge 33K 7700 2.0 2.125 YES 65 S-27 North Edge 33K 7700 2.0 2.0 YES Equipment ID: Ram No: 97-267 Pump No: 03196C Gauge No: 97-267 Equipment Calibration Date: 12/11/98 Comment8: ~ Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (I) Mr. Doyle Damron; C. D. Construction Consulffng LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persom or conditions over wh~c~ we have no control. Our letters and reports are for the exclusive use of the clients to whom they are c:\wpwin\reports\D7429-~56-98\ST January 13, 1999