Mansions Phase 1-LR 990112 (2) Ron~ Ef~§in~r~, If~. 1 :t~94 Goodr~ight Lane ~; TeL (972) 241-451-7--
! ineers
Da~las,'Fort Worth Do,Jas, Texas Metro (972) 263-19o5
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-345 I Date of Observation 12/15/98 Report Date 01/12/99
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 3 I Truck 734 I Ticket 3074788
Location BUILDING SLAB #13 - 75' NORTH, 30' WEST FROM SOUTHEAST CORNER
Time Sampled 2:06 Time Batched 1:10 Weather ConditiorrCLEAR
Concrete Temperature (OF) 62 Ambient Temperature (°F) 59 Mix Number 51
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
Concrete Cylinder Test(s)
Specimen I AgeI I Total Load Compressive
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
153A 7 12/22/98 90000 3180 3000/28 DAYS
B 28 1/12/99 120000 4240
C 28 1/12/99 131000 4630
D H
I
I
Curing Method I Test Method I Standard 6" x 12" Engineer/Technician S. SPARKMAN
ASTMC31I ASTMC39I Area 28.27 sq. in.
Signature: Mike Fuller, AET ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction-Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports\D7429-345-98\ST January 12, 1999