Loading...
Mansions Phase 1-LR 990104 (8) Dallas;Fort Wo¢~M Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-345 I Date of Observation 12/15/98 Report Date 01/04/99 To Western Rim Services Contractor Location BUILDING SLAB/fl 3 - 75' NORTH, 30' WEST FROM SOUTHEAST CORNER Time Sampled 2:06 Time Batched 1:10 Weather Condition CLEAR Concrete Temperature (°F) 62 Ambient Temperature (°F) 59 Mix Number 51 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5 1/2 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 1 53A 7 1 2/22/98 90000 3180 3000/28 DAYS B 28 1/1 2/99 C 28 1/12/99 D H I TestMeth°d I Standard 6" x12"Isq. Curing Method ASTM C 39 / Area 28.27 in. Engineer/Technician S. SPARKMAN ASTM C 31 Signature: Mike Fuller, AET {~ij~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are' addressed. c:\wpwin\reports\D7429-345-98\ST January 4, 1999