Mansions Phase 1-LR 990104 (6) Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-351 I Date of Observation 12/18/98 Report Date 1/04/99
To Western Rim Services
Contractor
Location SLAB AND GRADE BEAMS, BUILDING 12 - 15' EAST AND 10' SOUTH OF NORTHWEST CORNER
Time Sampled 11:10 Time Batched 10:05 Weather Condition CLOUDY
Concrete Temperature (OF) 58 Ambient Temperature (OF) 53 Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.5
ENTRAINED AIR (%) 3.6
Concrete Cylinder Test(s)
SpecimenI Age I Test Date l TOtal Load l Compressive
No, (Days) (lbs.) Strength (psi) Strength Required (psi)
157A 7 12/25/98 79000 2790 3000/28 DAYS
B 28 1/1 5/99
C 28 1/15/99
D H
Curing Method I TestMethod I Standard 6" x12" I Engineer/TechnicianS. CORLEY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET ~w.) Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr, Larry Davis; City of Coppell
(1) Mr, Mike Hodge; City of Coppell
(1) Mr, Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C, D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or cond~ions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are-
addressed.
c:',wpwin\reports',D7429-351-98\ST January 4, 1999